Canadian Energy Regulator Onshore Pipeline Regulations, SOR/99-294
Section 38
Cite as Canadian Energy Regulator Onshore Pipeline Regulations, SOR/99-294, s. 38 · current to July 24, 2025 · regulation last amended September 27, 2022
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) A company shall not perform welding on a liquid-filled pipeline with a carbon equivalent of 0.50% or greater except if it has been demonstrated that no other practical alternative is available.
(2) If a company performs welding referred to in subsection (1), the company shall treat the weld as a temporary installation and replace that installation with a permanent one as soon as is practicable.
(3) Despite subsections (1) and (2) and section 16, if a company intends to perform welding on a liquid-filled pipeline with a carbon equivalent of 0.50% or greater and to treat it as a permanent installation, the company shall submit the welding specifications and procedures and the results of the procedure qualification tests to the Commission for approval.
Read the Canadian Energy Regulator Onshore Pipeline Regulations on the Justice Laws Website ↗
Made under N-7.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.