Canada Oil and Gas Installations Regulations, SOR/96-118

Section 11

Cite as Canada Oil and Gas Installations Regulations, SOR/96-118, s. 11 · current to July 24, 2025 · regulation last amended October 6, 2020

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) Subject to subsections (2) to (4), all electric motors, lighting fixtures, electric wiring and other electrical equipment on an installation shall be designed, installed and maintained in accordance with (a) in the case of an onshore installation, Canadian Standards Association Standard C22.l-l990, Canadian Electrical Code Part I, Safety Standard for Electrical Installations; and (b) in the case of an offshore installation, American Petroleum Institute RP l4F, Recommended Practice for Design and Installation of Electrical Systems for Offshore Production Platforms. (2) Electrical wiring on an offshore installation shall be (a) designed in accordance with International Electrotechnical Commission Publication 92-3, Electrical Installations in Ships, Part 3: Cables (construction, testing and installations) and tested for Category A in accordance with International Electrotechnical Commission Publication 332-3, Tests on electrical cables under fire conditions, Part 3: Tests on bunched wires or cables; and (b) tested for impact at -35°C and bending at -40°C in accordance with Canadian Standards Association Standard C22.2 No. 0.3-M1985, Test Methods for Electrical Wires and Cables. (3) Where a primary or secondary distribution system for power, heating or lighting, with no connection to earth, is used on an offshore installation, a device capable of continuously monitoring the insulation level to earth and of giving an audible or visual indication of abnormally low insulation values shall be provided. (4) The primary source of electrical power on every offshore installation shall (a) include at least two power plants; (b) be capable of supporting all normal operations without recourse to the emergency source of electrical power required by section 12; and (c) if one of the power plants is out of operation, be capable of supporting all operations except drilling and production operations. (5) The primary circuits from the power plant serving an installation shall be equipped with at least two manual shut-off switches, each at a different location.
Read the Canada Oil and Gas Installations Regulations on the Justice Laws Website ↗

Made under Canada Oil and Gas Operations Act, R.S.C. 1985, c. O-7.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.