Coal Mining Occupational Health and Safety Regulations, SOR/90-97
Section 29
Cite as Coal Mining Occupational Health and Safety Regulations, SOR/90-97, s. 29 · current to July 24, 2025 · regulation last amended January 1, 2021
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Where all of a round of shots misfire, the shotfirer shall, in the following sequence,
(a) remove the handle or key from the blasting machine and disconnect the shotfiring cable from the blasting machine;
(b) twist the ends of the shotfiring cable together at the blasting machine and isolate them from ground;
(c) wait 15 minutes;
(d) test the circuit for electrical continuity; and
(e) if the test shows that there is electrical continuity, attempt to fire the round using either the same blasting machine or another blasting machine that is suitable for the purpose.
(2) Where the test referred to in paragraph (1)(e) shows that there is no electrical continuity, or where the attempt referred to in that paragraph fails, the shotfirer shall, in the following sequence,
(a) remove the handle or key from the blasting machine and disconnect the shotfiring cable from the blasting machine;
(b) twist the ends of the shotfiring cable together at the blasting machine and isolate them from ground;
(c) wait 15 minutes;
(d) disconnect the shotfiring cable and detonator lead wires at each shot hole;
(e) test for electrical continuity in the shotfiring cable and detonator lead wires;
(f) test the blasting machine; and
(g) if the tests show that there is electrical continuity, the detonator lead wires and the shotfiring cable shall be reconnected and tested for electrical continuity and a further attempt shall be made to fire the round.
(3) Where any of the tests referred to in paragraphs (2)(e) to (g) do not produce the desired result, the shotfirer shall install barricades and post a warning sign in accordance with subsection 31(1).
(4) Where a single shot in a round misfires and is recovered, or where a part of a round of shots misfires and is recovered, the shotfirer shall sort the debris by hand, recover all explosives and detonators from the debris and take them to the structure referred to in subsection 11(2).
Read the Coal Mining Occupational Health and Safety Regulations on the Justice Laws Website ↗
Made under Canada Labour Code, R.S.C. 1985, c. L-2.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.