Coal Mining Occupational Health and Safety Regulations, SOR/90-97
Section 25
Cite as Coal Mining Occupational Health and Safety Regulations, SOR/90-97, s. 25 · current to July 24, 2025 · regulation last amended January 1, 2021
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Where a shot is to be fired with a blasting machine, the shotfiring cable shall be not less than 30 m long.
(2) No person, other than a shotfirer, shall connect a shotfiring cable to detonator wires or to a blasting machine.
(3) Where a shot is to be fired with a blasting machine, the shotfirer shall, in the following sequence,
(a) twist the ends of the shotfiring cable together at the blasting machine and isolate them from ground;
(b) check the shotfiring cable and the detonator circuit;
(c) connect the shotfiring cable to the shot;
(d) check the total circuit;
(e) verify that all persons in the danger area referred to in paragraph 22(1)(a) have been evacuated from that area;
(f) connect the shotfiring cable to the blasting machine, verifying that the shotfirer alone has possession and control of the blasting machine;
(g) shout “FIRE” or “TIR”;
(h) verify that the danger area referred to in paragraph 22(1)(a) is clear of persons;
(i) take cover outside the danger area referred to in paragraph 22(1)(a);
(j) fire the shot;
(k) subject to sections 28 and 29, wait at least five minutes before the shotfirer returns to the area of the shot hole to satisfy himself that no dangerous condition has resulted from firing the shot; and
(l) measure the concentration of flammable gas in the general body of the air in the area of the shot hole.
Read the Coal Mining Occupational Health and Safety Regulations on the Justice Laws Website ↗
Made under Canada Labour Code, R.S.C. 1985, c. L-2.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.