Coal Mining Occupational Health and Safety Regulations, SOR/90-97

Section 21

Cite as Coal Mining Occupational Health and Safety Regulations, SOR/90-97, s. 21 · current to July 24, 2025 · regulation last amended January 1, 2021

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

A shotfirer shall, immediately before charging a shot hole underground, (a) subject to subsection 27(3), verify, using a methanometer and a locked-flame safety lamp, that the concentration of flammable gas in the general body of the air in the area of the shot hole and in any area contiguous thereto does not exceed 1.25 per cent; (b) examine the shot hole to verify that it has been thoroughly cleaned; (c) verify that the shot hole does not intersect any cracks or crevices greater than 3 mm; (d) verify that the shot hole is at least 3 mm larger than the diameter of the cartridge of the explosive to be used; (e) place a plug of stemming in the back of the shot hole; and (f) verify that any dust in the area of the shot hole has been treated with stone dust to a minimum of three 25 kg bags of stone dust per metre of advance.
Read the Coal Mining Occupational Health and Safety Regulations on the Justice Laws Website ↗

Made under Canada Labour Code, R.S.C. 1985, c. L-2.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.