Coal Mining Occupational Health and Safety Regulations, SOR/90-97
Section 134
Cite as Coal Mining Occupational Health and Safety Regulations, SOR/90-97, s. 134 · current to July 24, 2025 · regulation last amended January 1, 2021
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Every roadway underground shall be treated with incombustible dust in such a way that the dust on the floor, roof and sides of the roadway contains
(a) where the concentration of flammable gas in the air in the roadway does not exceed 1 per cent, not less than 75 per cent by weight of incombustible dust; and
(b) where the concentration of flammable gas in the air in the roadway exceeds 1 per cent, not less than 80 per cent by weight of incombustible dust.
(2) Subject to subsection (3), the incombustible dust referred to in subsection (1) shall contain not less than 70 per cent by weight of fine material that is capable, when dry, of passing through a sieve of 200 mesh.
(3) Where a larger percentage of incombustible dust than the percentage referred to in subsection (1) is used, the percentage of fine material referred to in subsection (2) may be reduced in proportion to the increase in the amount of incombustible dust, but in no case shall it be less than 25 per cent.
Read the Coal Mining Occupational Health and Safety Regulations on the Justice Laws Website ↗
Made under Canada Labour Code, R.S.C. 1985, c. L-2.