(1) Methanometers at the intake and return ends of a longwall face shall be designed to continually (a) measure the concentration of flammable gas in the air; (b) display the concentration of flammable gas; and (c) record the concentration of flammable gas. (2) The record referred to in paragraph (1)(c) shall be displayed (a) where the concentration is recorded remotely, for a period of at least 24 hours after it is made; and (b) in any other case, for a period of at least two hours after it is made. (3) Where remote monitoring of flammable gas is carried out, there shall be a qualified person at the remote monitoring station at all times. (4) The mine manager shall establish and keep at the remote monitoring station procedures to be followed by a qualified person referred to in subsection (3) whenever an audible alarm is sounded.