Where the concentration of flammable gas exceeds 0.8 per cent in a location underground where electrical equipment or a diesel engine is operated or where a source of ignition is present, a test for gas shall be made in that location, using a methanometer, at least once every eight hours for as long as the concentration of flammable gas exceeds 0.8 per cent.