Coal Mining Occupational Health and Safety Regulations, SOR/90-97
Section 116
Cite as Coal Mining Occupational Health and Safety Regulations, SOR/90-97, s. 116 · current to July 24, 2025 · regulation last amended January 1, 2021
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Where a main fan, booster fan or auxiliary fan stops for any reason, every person who is in an area that is affected by the stoppage shall be evacuated to a place that is ventilated in accordance with subsection 110(1).
(2) A qualified person shall, before any other person enters an area that has been evacuated pursuant to subsection (1), inspect the area to determine whether it is ventilated in accordance with subsection 110(1).
(3) Where a main fan or booster fan stops for any reason for more than 30 minutes, the mine manager shall, without delay, submit a written report of the circumstances under which it stopped to a safety officer at the district office.
(4) Where an auxiliary fan stops, no person shall restart the auxiliary fan unless a qualified person has
(a) inspected the area underground that is serviced by the auxiliary fan and has tested for flammable gases; and
(b) informed the person that it is safe to restart the auxiliary fan.
(5) The mine manager shall prepare procedures to be followed in the event of the stoppage of an auxiliary fan and shall post a copy of those procedures in a conspicuous place at the surface of the coal mine.
Read the Coal Mining Occupational Health and Safety Regulations on the Justice Laws Website ↗
Made under Canada Labour Code, R.S.C. 1985, c. L-2.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.