Coal Mining Occupational Health and Safety Regulations, SOR/90-97
Section 114
Cite as Coal Mining Occupational Health and Safety Regulations, SOR/90-97, s. 114 · current to July 24, 2025 · regulation last amended January 1, 2021
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Every main fan shall be
(a) equipped with devices that are capable of reversing the airflow controlled by the main fan;
(b) located above ground in a fan house constructed of non-flammable materials; and
(c) offset from all shafts or connections to the underground portions of the coal mine.
(2) Every fan house referred to in paragraph (1)(b) shall be provided with a pressure release door or other device that is easily opened by the force of an explosion.
(3) No combustible material shall be stored in a fan house referred to in paragraph (1)(b).
Read the Coal Mining Occupational Health and Safety Regulations on the Justice Laws Website ↗
Made under Canada Labour Code, R.S.C. 1985, c. L-2.