Canada Oil and Gas Diving Regulations, SOR/88-600

Section 47

Cite as Canada Oil and Gas Diving Regulations, SOR/88-600, s. 47 · current to July 24, 2025 · regulation last amended March 22, 2006

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) No supervisor shall conduct a diving operation unless (a) the diving plant and equipment referred to in paragraph 9(5)(h) meets the relevant requirements of sections 12 to 21, is available for use when required and that diving plant and equipment, other than diving plant and equipment intended to be mobile during the diving operation, is, at all times during the diving operation, firmly secured to the craft or installation from which the diving operation is conducted; and (b) any electrically operated diving plant and equipment that is used in the diving operation is suitable for the location in which it is to be used and is protected from hazards caused by water and environmental conditions. (2) No supervisor shall, in a diving operation supervised by the supervisor, use any diving plant and equipment in the diving operation unless (a) the appropriate examinations and tests referred to in subsection 11(1) have been carried out on the diving plant and equipment and the certificates related to those examinations and tests have been inserted into or attached to the register referred to in subsection 11(3); and (b) the supervisor has, not more than 24 hours before such use, (i) examined the diving plant and equipment in accordance with the relevant provisions of the applicable procedures manual and found it to be in good working order, and (ii) where appropriate, in addition to the examination referred to in subparagraph (i), tested for leaks any pump, compressor, cylinder or pipeline used in the diving operation to convey breathing mixture and found it free from leaks. (3) No diving supervisor shall conduct a dive unless a two-compartment compression chamber (a) that has been approved in accordance with section 5 for the diving program of which the dive is a part, to be used at a pressure that is not less than six atmospheres absolute and, where the maximum working pressure that may be encountered during the dive is greater than six atmospheres absolute, at the maximum working pressure plus one atmosphere, and (b) that is suitable for the diveis located in a readily accessible place on board the craft or installation from which the dive is conducted, except where the dive is conducted at a depth of 10 m or less, in which case the compression chamber may be located within one hour’s travelling time from the dive site.
Read the Canada Oil and Gas Diving Regulations on the Justice Laws Website ↗

Made under Canada Oil and Gas Operations Act, R.S.C. 1985, c. O-7.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.