Oil and Gas Occupational Safety and Health Regulations, SOR/87-612
Section 3.9
Cite as Oil and Gas Occupational Safety and Health Regulations, SOR/87-612, s. 3.9 · current to February 4, 2026 · regulation last amended January 30, 2026
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Every guardrail shall consist of
(a) a horizontal top rail or line not less than 900 mm and not more than 1 100 mm above the base of the guardrail;
(b) a horizontal intermediate rail or line spaced midway between the top rail or line and the base of the guardrail; and
(c) supporting posts spaced not more than 3 m apart at their centres.
(2) Every guardrail shall be designed to withstand the greater of
(a) the maximum load that is likely to be imposed on it; and
(b) a static load of not less than 890 N applied in any direction at any point on the top rail or line.
Read the Oil and Gas Occupational Safety and Health Regulations on the Justice Laws Website ↗
Made under Canada Labour Code, R.S.C. 1985, c. L-2.