(1) Subject to subsection (5), a fixed ladder that is more than 6 m in length shall, where practicable, be fitted with a protective cage for that portion of its length that is more than 2 m above the base level of the ladder.
(2) Subject to subsection (5), a fixed ladder that is more than 9 m in length shall have, at intervals of not more than 6 m, a landing or platform that
(a) is not less than 0.36 m2 in area; and
(b) is fitted at its outer edges with a guardrail.
(3) A fixed ladder, cage, landing or platform referred to in subsection (1) or (2) shall be designed and constructed to withstand all loads that may be imposed on it.
(4) A fixed ladder shall be
(a) vertical;
(b) securely held in place at the top, bottom and at intermediate points; and
(c) fitted with
(i) rungs that are at least 150 mm from the wall and uniformly spaced at intervals not exceeding 300 mm, and
(ii) side rails that extend not less than 900 mm above the landing or platform.
(5) Subsections (1) and (2) do not apply to a fixed ladder that is used with a fall protection system referred to in section 13.10 of Part XIII.