(1) In this section,
floor opening means an opening measuring 300 mm or more in its smallest dimension in a floor, platform, pavement or yard; (ouverture dans un plancher)
wall opening means an opening at least 750 mm high and 300 mm wide in a wall or partition. (ouverture dans un mur)
(2) Where an employee has access to a wall opening from which there is a drop of more than 1.2 m or to a floor opening, guardrails shall be fitted around the wall opening or floor opening or the opening shall be covered with material capable of supporting all loads that may be imposed on it.
(3) The material referred to in subsection (2) shall be securely fastened to a supporting structural member of the building.
(4) Subsection (2) does not apply to the loading and unloading areas of truck, railroad and marine docks.
(5) Subject to section 3.10, guardrails shall be installed around the perimeter of every work place, other than a helicopter deck, where there is a drop of more than 1 m from the work place to an adjacent area.
Read the Oil and Gas Occupational Safety and Health Regulations on the Justice Laws Website ↗
Made under Canada Labour Code, R.S.C. 1985, c. L-2.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.