Oil and Gas Occupational Safety and Health Regulations, SOR/87-612

Section 3.14

Cite as Oil and Gas Occupational Safety and Health Regulations, SOR/87-612, s. 3.14 · current to February 4, 2026 · regulation last amended January 30, 2026

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) Subject to subsection (2), where a salamander or other portable open-flame heating device is used in an enclosed work place, the heating device shall not restrict a means of exit and shall be (a) so located, protected and used that there is no hazard of igniting combustible materials adjacent to the heating device; (b) used only when there is ventilation provided that protects the safety and health of employees; and (c) so located as to be protected from damage or overturning. (2) Where the heating device referred to in subsection (1) does not provide complete combustion of the fuel used in connection with it, the heating device shall be equipped with a securely supported sheet metal pipe that discharges the products of combustion outside the enclosed work place. (3) A portable fire extinguisher that has not less than a 10B rating as defined in the ULC Standard shall be readily accessible from the location of the heating device referred to in subsection (1) when the device is in use.
Read the Oil and Gas Occupational Safety and Health Regulations on the Justice Laws Website ↗

Made under Canada Labour Code, R.S.C. 1985, c. L-2.