(1) Every double-action swinging door that is located in an exit, entrance or passageway used for two-way pedestrian traffic or traffic involving wheelchairs or other similar devices shall be designed and fitted in a manner that will allow persons who are approaching from one side of the door to be aware of persons who are on the other side of it.
(2) The area of every passageway into which a door or gate extends when open, other than the door of a closet or other small unoccupied storage room, shall be marked, in consultation with the work place committee or the health and safety representative in a manner that clearly indicates the area of hazard created by the opening of the door or gate.
(3) Where a door or gate that is to remain open extends into a passageway for a distance that will reduce the effective width of the passageway to a width less than that required by the National Building Code,
(a) an attendant shall be posted near the open door or gate; or
(b) a highly visible barricade shall be placed across the passageway before the door or gate is opened to prevent persons from using the passageway while the door or gate is open.