Canada Occupational Health and Safety Regulations, SOR/86-304

Section 2.10

Cite as Canada Occupational Health and Safety Regulations, SOR/86-304, s. 2.10 · current to February 18, 2026 · regulation last amended March 26, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) Every grain-handling facility that has a manlift or ladder that provides access to a floor or roof over a grain bin or silo shall, in addition to its primary exit, have a secondary exit from the floor or roof that consists of an exterior fixed ladder constructed in accordance with the requirements referred to in subsection 2.9(1). (2) A fixed ladder that is installed in a grain-handling facility before the day of the coming into force of this section shall, if feasible, meet the requirements referred to in subsection 2.9(1). (3) A fixed ladder that is installed adjacent to a manlift and that is intended for emergency exit from the manlift shall meet the requirements of section 5.1.9 of CSA Standard B 311-M1979, entitled Safety Code for Manlifts, the English version of which is dated October 1979 and the French version of which is dated July 1984.
Read the Canada Occupational Health and Safety Regulations on the Justice Laws Website ↗

Made under Canada Labour Code, R.S.C. 1985, c. L-2.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.