Railway Prevention of Electric Sparks Regulations, SOR/82-1015
Section 5
Cite as Railway Prevention of Electric Sparks Regulations, SOR/82-1015, s. 5 · current to July 24, 2025 · regulation last amended March 22, 2006
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Where the grounding required by section 4 is difficult to implement owing to local conditions, the railway company shall take such additional measures, including the installation of insulated joints in the piping system, the provision of additional ground rods or the provision of additional bonds between the piping system and the units of rolling stock, as may be required to ground the section of railway track.
(2) Where the tanks of a piping system have cathodic protection, the tanks shall be grounded in a manner that does not interfere with the cathodic protection.
(3) Insulated rail joints that are installed as required by paragraph 4(e) shall not be bridged by rolling stock or by any other means during the transfer operations.
Read the Railway Prevention of Electric Sparks Regulations on the Justice Laws Website ↗
Made under Railway Safety Act, R.S.C. 1985, c. 32 (4th Supp.).