Clean Electricity Regulations, SOR/2024-263
Section 24
Emissions — hydrogen, ammonia or steam (Eext)
Cite as Clean Electricity Regulations, SOR/2024-263, s. 24 · current to July 24, 2025 · regulation last amended January 1, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) The quantity of CO2 emissions from the production of the hydrogen, ammonia or steam used by a unit to generate electricity during a calendar year is determined by the formulaThe sum of the multiplication of Qk by the quotient of Ek and Pk, summed for each stream “k” of hydrogen, ammonia and steam.wherekis the kth stream of hydrogen, ammonia or steam, where “k” goes from 1 to n and where n is the number of streams of hydrogen, ammonia or steam that are used by the unit during the calendar year;Ekis the total annual CO2 emissions, expressed in tonnes, from the total annual production of the kth stream of hydrogen, ammonia or steam used by the unit during the calendar year;Pkis the total annual production of the kth stream of hydrogen, ammonia or steam during the calendar year, determined using a continuous measuring device and expressed(a) in m3 at standard conditions, in the case of hydrogen and ammonia, and(b) in GJ, in the case of steam; andQkis the quantity of hydrogen or ammonia, expressed in m3 at standard conditions, or the quantity of purchased or transferred steam, expressed in GJ, in the kth stream used by the unit to generate electricity during the calendar year, determined using a continuous measuring device.
(2) Subject to subsection (4), the responsible person must obtain the values of Ek and Pk from the supplier of the hydrogen, ammonia or steam, if any, used by the unit, determined in accordance with
(a) section 10 of the GHGRP, in the case of hydrogen production;
(b) section 8 of the GHGRP, in the case of ammonia production; and
(c) section 7 of the GHGRP, in the case of steam production.
(3) For the purposes of paragraph (2)(a), the description of RCO2 in Equation 10-2 of the GHGRP is to be read as “CO2 captured and permanently stored in a storage project that meets the conditions set out in subsection 23(2) of the Clean Electricity Regulations”.
(4) If the hydrogen or ammonia used by a unit is not produced at the facility at which the unit is located or the steam used by a unit is purchased or transferred to that facility and the responsible person for the unit is not able to obtain from the supplier the information required under subsection (2), the responsible person must replace the ratio Ek ÷ Pk in subsection (1) with the following values:
(a) 9.8312 × 10-4 tonnes of CO2/m3, in the case of hydrogen;
(b) 1.4635 × 10-3 tonnes of CO2/m3, in the case of ammonia; and
(c) 0.08 tonnes of CO2/GJ, in the case of steam.
Read the Clean Electricity Regulations on the Justice Laws Website ↗
Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.