Clean Electricity Regulations, SOR/2024-263

Section 21

Attributed emissions (Eth)

Cite as Clean Electricity Regulations, SOR/2024-263, s. 21 · current to July 24, 2025 · regulation last amended January 1, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

The quantity of CO2 emissions attributed to the production of useful thermal energy by a unit during a calendar year is determined by the formulaHpnet × bEIwhereHpnetis the net quantity of useful thermal energy, expressed in GJ, determined by the formulaThe sum of the products of houti and Mouti for each heat stream “i” minus the sum of the products of hinj and Minj for each heat stream “j”, summed for all time periods.wheretis the tth period, where “t” goes from 1 to x and where x is the total number of periods during which the unit produced useful thermal energy during the calendar year,iis the ith heat stream exiting the unit, where “i” goes from 1 to n and where n is the total number of heat streams exiting the unit,houtiis the average specific enthalpy of the ith heat stream exiting the unit during period “t”, expressed in GJ/tonne and determined based on the measurement, using a continuous measuring device, of the temperature and pressure of that heat stream,Moutiis the mass flow of the ith heat stream exiting the unit during period “t”, expressed in tonnes and determined using a continuous measuring device,jis the jth heat stream, other than condensate return, entering the unit, where “j” goes from 1 to m and where m is the total number of heat streams entering the unit,hinjis the average specific enthalpy of the jth heat stream, other than condensate return, entering the unit during period “t”, expressed in GJ/tonne and determined based on the measurement, using a continuous measuring device, of the temperature and pressure of that heat stream, andMinjis the mass flow of the jth heat stream, other than condensate return, entering the unit during period “t”, expressed in tonnes and determined using a continuous measuring device; andbEIis the emission intensity of a reference boiler, set to 0.0556 tonnes of CO2 emissions per GJ.
Read the Clean Electricity Regulations on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.