Clean Electricity Regulations, SOR/2024-263
Section 17
Units sharing CEMS
Cite as Clean Electricity Regulations, SOR/2024-263, s. 17 · current to July 24, 2025 · regulation last amended January 1, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
If a unit is located at a facility where there are one or more other units and a CEMS measures emissions from that unit and at least one other unit at a common stack rather than at the exhaust duct of each unit that shares the common stack, the quantity of CO2 emissions attributed to that unit is determined, based on the ratio of the heat input of that unit to the total heat input of all the units sharing the common stack, by the formulaThe product of the multiplication of E and the quotient of the following two sums: the sum of the product resulting from the multiplication of Quj and HHVuj for each fuel type “j” combusted in that unit “u” during the calendar year and the sum, for each unit “i” that shares a common stack, of the sum of the product resulting from the multiplication of Qij and HHVij for each fuel type “j” combusted during the calendar year.wherejis the jth fuel type combusted during the calendar year in a unit where “j” goes from 1 to y and where y is the number of fuel types combusted;Qu,jis the quantity of fuel type “j” combusted in the unit “u” during the calendar year, determined(a) for a gaseous fuel, in the same manner used in the determination of Vf in paragraph 20(1)(a) and expressed in m3 at standard conditions,(b) for a liquid fuel, in the same manner used in the determination of Vf in paragraph 20(1)(b) and expressed in kL, and(c) for a solid fuel, in the same manner used in the determination of Mf in paragraph 20(1)(c) and expressed in tonnes;HHVu,jis the higher heating value for each fuel type “j” combusted in the unit “u” that is measured in accordance with subsection 16(2) or the default higher heating value set out in column 2 of Schedule 3 for the fuel type set out in column 1;iis the ith unit, where “i” goes from 1 to x and where x is the number of units that share the common stack;Qi,jthe quantity of fuel type “j” combusted in each unit “i” during the calendar year, determined for a gaseous fuel, a liquid fuel and a solid fuel, respectively, in the manner set out in the description of Qu,j;HHVi,jis the higher heating value for each fuel type “j” combusted in each unit “i” that is measured in accordance with subsection 16(2) or the default higher heating value set out in column 2 of Schedule 3 for the fuel type set out in column 1; andEis the quantity of CO2 emissions, expressed in tonnes, from the combustion of all fuels in all the units that share the common stack during the calendar year, measured using a CEMS at the common stack and determined in accordance with sections 7.1 to 7.5 of the CEMS Protocol.
Read the Clean Electricity Regulations on the Justice Laws Website ↗
Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.