Canada–Nova Scotia Offshore Area Petroleum Operations Framework Regulations, SOR/2024-26
Section 131
Gas release system
Cite as Canada–Nova Scotia Offshore Area Petroleum Operations Framework Regulations, SOR/2024-26, s. 131 · current to September 21, 2026 · regulation last amended September 17, 2026
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) An operator must ensure that an installation that includes process tanks, process vessels and piping is equipped with a gas release system that has a flaring system, a pressure relief system, a depressurizing system or a cold vent system.
(2) The operator must ensure that the design of the gas release system is based on the results of the risk assessment conducted under subsection 107(1).
(3) The operator must ensure that the gas release system is designed to
(a) release gas and combustible liquid from an installation in a controlled manner without creating a hazard to safety;
(b) reduce pressure in the entire process system as quickly as possible while ensuring a safe and controlled release of pressure;
(c) minimize the effect on the environment;
(d) be activated from the main control centre and from control stations that meet the requirements set out in subsection (5); and
(e) ensure that oxygen cannot enter the system during normal operations.
(4) The operator must ensure that the gas release system is designed and located taking into account factors, including physical and environmental conditions, that affect the safe and normal flaring or emergency release of combustible liquid, gases or vapours so that when the system is in operation it does not damage the installation — or any other installation, vessel or support craft in proximity to it — or injure any person.
(5) The operator must ensure that the control stations from which the gas release system is activated are located and spaced so that they remain protected and accessible for safe operation of the system.
(6) The operator must, in respect of any flaring system, ensure that
(a) if an unlit release of gas could produce toxic gas concentrations or gas concentrations of more than 50% of the lower explosive limit of the released gas,
(i) the system has an automatic igniter system that has redundancy in its ignition capabilities, and
(ii) in the case of an open flare system, the system and any associated equipment are designed to ensure a continuous flame; and
(b) the system and any associated equipment are designed to
(i) withstand the radiated heat at the maximum flaring rate,
(ii) prevent flashback, and
(iii) withstand all loads to which they may be subjected.
(7) The operator must ensure that any vent that is used to release gas into the atmosphere without combustion is designed and located in accordance with the measures referred to in clause 9(2)(b)(vi)(A) and subparagraph 10(2)(b)(vi) that are described in the operator’s safety plan and environmental protection plan, respectively.
(8) The operator must ensure that any liquid, other than water, that cannot be safely and reliably burned at the flare tip of a gas release system is removed from the gas before it enters the flare.
Read the Canada–Nova Scotia Offshore Area Petroleum Operations Framework Regulations on the Justice Laws Website ↗
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.