Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations, SOR/2024-25

Section 163

Drilling fluid systems

Cite as Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations, SOR/2024-25, s. 163 · current to September 21, 2026 · regulation last amended September 17, 2026

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

An operator must ensure that (a) the drilling fluid system and associated monitoring equipment provide an effective barrier against formation pressure, ensure safe well operations, prevent pollution and allow for well evaluation; (b) the indicators and alarms associated with the monitoring equipment are strategically located on the drilling rig to alert persons on it; and (c) dedicated personnel provide continuous monitoring, using independent monitoring systems, of parameters that are critical to safe well operations or to the detection of a gain or loss of drilling fluid while the installation is connected to the well and is taking fluid returns.
Read the Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations on the Justice Laws Website ↗

Made under Canada–Newfoundland and Labrador Atlantic Accord Implementation and Offshore Renewable Energy Management Act, S.C. 1987, c. 3.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.