Canada–Nova Scotia Offshore Area Occupational Health and Safety Regulations, SOR/2021-248

Section 144

Employer obligations

Cite as Canada–Nova Scotia Offshore Area Occupational Health and Safety Regulations, SOR/2021-248, s. 144 · current to July 24, 2025 · regulation last amended January 1, 2022

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) Every employer must ensure, at each workplace under its control, that (a) hazardous energy is controlled in accordance with CSA Group standard Z460, Control of hazardous energy — Lockout and other methods; (b) every energy-isolating device is (i) designed and located to permit its quick and safe operation at all times, and (ii) marked to identify, in the manner referred to in subparagraph 142(a)(i), the equipment, machine, device or system whose energy source it isolates; (c) lockout devices and locks for securing them are readily available to employees who may need to carry out a lockout; (d) every lock used to secure a lockout device is (i) marked with a unique identification number, and (ii) openable only with a unique key; (e) no lockout device is secured on an energy-isolating device in a manner that prevents access to any other energy-isolating device; (f) every employee who secures a lockout device affixes to it a tag or sign containing only the following information: (i) the equipment, machine, device or system whose energy source has been isolated and the type of energy that has been isolated, (ii) words or a symbol prohibiting any person from starting or operating the equipment, machine, device or system, (iii) the date and time of the lockout, (iv) the name of the employee who secured the lockout device, and (v) the reason for the lockout; (g) no tag or sign is removed from a lockout device by anyone other than the employee who affixed it or to whom control of the device has been transferred in accordance with the procedures referred to in paragraph 142(d); (h) any equipment, machine, device or system that has been locked out is inspected before being returned to service; (i) all electrical equipment is adequately guarded, insulated and, subject to paragraph 91(1)(i), grounded to prevent electrical hazards; (j) all grounded electrical equipment that plugs into an electrical receptacle meets the following requirements: (i) its cord, if any, contains a grounding conductor, (ii) its plug and the receptacle into which the plug is inserted are not (A) connected or altered in a manner that might interrupt the continuity of the grounding conductor, or (B) altered to allow for use in a manner not intended by the manufacturer, and (iii) it is not used with an adapter that would interrupt the continuity of the grounding conductor; (k) work is not carried out on electrical equipment while it is energized unless necessary due to equipment design or operational limitations; (l) a competent person identifies, using an arc flash analysis, all electrical equipment that poses an arc flash hazard and that equipment has affixed to it a warning label setting out the date of the analysis and the following information reflecting the analysis: (i) the equipment’s nominal voltage, (ii) the arc flash boundary for the equipment, and (iii) an indication of (A) the available incident energy and corresponding working distance in respect of the equipment, (B) the arc flash category of personal protective equipment that must be used with the equipment, (C) the minimum arc rating of personal protective equipment that must be used with the equipment, or (D) the site-specific level of personal protective equipment that must be used with the equipment; (m) only the following persons work on energized electrical equipment used for the generation or distribution of electricity or install, repair, alter or test electrical equipment: (i) a person who is certified as an electrician under the laws of a province, (ii) a person who has qualifications from a jurisdiction outside of Canada equivalent to those of a person referred to in subparagraph (i), and (iii) a person who is undergoing on-the-job training under the direct supervision of a person referred to in subparagraph (i) for the purpose of becoming such a person and who has demonstrated an ability to perform tasks safely at their level of training; (n) electrical equipment is installed in a location that minimizes risk to the safety of persons and in a manner that protects the equipment from mechanical and other damage; (o) the working space around and the path of access to every electrical switch, energy-isolating device or meter are free from obstruction and arranged to give authorized persons ready access to them; (p) electrical rooms are not used for storing flammable, explosive or combustible materials or materials that are unrelated to electrical work; (q) volatile flammable substances are not used in any electrical room or other enclosed area through which high-voltage electrical current passes; (r) all electrical equipment that is used in an area referred to in subsection 26(2) has been certified by a competent person who is independent of the operator, employer and manufacturer as being safe for use in such an area; (s) any electrical receptacle or extension cord that is used in an area referred to in subsection 26(2) is equipped with a terminal that interrupts the circuit before a connecting device is withdrawn; (t) all electrical receptacles that may be exposed to weather are weatherproof; (u) all electrical receptacles in an area in which persons may be exposed to water, including within 1.5 m of faucets and showers, are designed or equipped to prevent ground faults; (v) precautions are taken to prevent a plug from being inserted into an electrical receptacle of the incorrect voltage; (w) electrical drawings, produced by a competent person and containing line diagrams indicating the position and voltage rating of all electrical components at the workplace, are made readily available to all persons at the workplace and are updated after any repair or alteration to the electrical system; (x) legible warning signs, written in the official operating language of the workplace with symbols to convey the same meaning, are posted wherever an electrical hazard exists; and (y) a non-conductive rescue hook is kept readily available for use wherever a person is carrying out work that may expose them to a shock hazard. (2) If the energy source being isolated is electric, the tag or sign referred to in paragraph (1)(f) must be made of non-conductive material. (3) The employer must ensure that (a) an energy-isolating device used on a pipe that contains a substance that may release hazardous energy, other than in a confined space, (i) consists of a blank or blind in conjunction with valves or other blocking seals that are secured and locked out in the closed position to prevent the substance from reaching the blank or blind, (ii) consists of a double block and bleed system consisting of two valves or other blocking seals that are secured and locked out in the closed position and located on each side of a valve or other mechanism that is secured and locked out in the open position to allow for bleed-off between the two seals, or (iii) has been approved by a professional engineer; (b) the location of any blank or blind referred to in subparagraph (a)(i) is clearly marked on the pipe; (c) all valves or other seals or mechanisms referred to in subparagraph (a)(i) or (ii) are clearly marked to indicate the position they are in; and (d) any energy-isolating device referred to in subparagraph (a)(ii) or (iii) is monitored for leaks. (4) The employer must ensure that electrical equipment that is taken out of service under section 88 is de-energized until a competent person determines it to be safe for use.
Read the Canada–Nova Scotia Offshore Area Occupational Health and Safety Regulations on the Justice Laws Website ↗

Made under Canada–Nova Scotia Offshore Petroleum Resources Accord Implementation and Offshore Renewable Energy Management Act, S.C. 1988, c. 28.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.