Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations, SOR/2021-247

Section 84

Wall and floor openings and open edges

Cite as Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations, SOR/2021-247, s. 84 · current to July 24, 2025 · regulation last amended January 1, 2022

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

Every employer must ensure that, in any area on a marine installation or structure under its control to which a person might have access, (a) every opening in a wall, partition or bulkhead that measures at least 75 cm high and 30 cm wide and from which there is a drop of more than 1.2 m, or that otherwise poses a hazard to any person, and every opening in a floor, platform or deck whose smallest dimension measures at least 30 cm is (i) protected by a guard-rail, or (ii) covered with material that is (A) securely fastened to a supporting structural member of the marine installation or structure, and (B) capable of withstanding all loads that are likely to be imposed on it; and (b) every other open edge from which there is a drop of more than 1.2 m, other than on a helicopter deck, is protected by a guard-rail.
Read the Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations on the Justice Laws Website ↗

Made under Canada–Newfoundland and Labrador Atlantic Accord Implementation and Offshore Renewable Energy Management Act, S.C. 1987, c. 3.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.