Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations, SOR/2021-247
Section 84
Wall and floor openings and open edges
Cite as Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations, SOR/2021-247, s. 84 · current to July 24, 2025 · regulation last amended January 1, 2022
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
Every employer must ensure that, in any area on a marine installation or structure under its control to which a person might have access,
(a) every opening in a wall, partition or bulkhead that measures at least 75 cm high and 30 cm wide and from which there is a drop of more than 1.2 m, or that otherwise poses a hazard to any person, and every opening in a floor, platform or deck whose smallest dimension measures at least 30 cm is
(i) protected by a guard-rail, or
(ii) covered with material that is
(A) securely fastened to a supporting structural member of the marine installation or structure, and
(B) capable of withstanding all loads that are likely to be imposed on it; and
(b) every other open edge from which there is a drop of more than 1.2 m, other than on a helicopter deck, is protected by a guard-rail.
Read the Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations on the Justice Laws Website ↗
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.