Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations, SOR/2021-247
Section 73
Minimum levels
Cite as Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations, SOR/2021-247, s. 73 · current to July 24, 2025 · regulation last amended January 1, 2022
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
Every employer must, in respect of each workplace under its control, ensure that
(a) all persons at the workplace have sufficient lighting — in terms of both quantity and quality — to perform all of their tasks safely; and
(b) if the workplace is a marine installation or structure, the average level of lighting at a work position or in an area referred to in column 1 of the following table is not less than that set out in column 2 when the workplace’s primary lighting system is operational.TABLEColumn 1Column 2ItemWork Position or AreaMinimum Average Level (in lx)1Office areas:(a) work positions at which cartography, drafting, plan reading or other tasks requiring high visual precision are performed800(b) work positions at which business machines are operated or prolonged reading or writing tasks are performed500(c) other areas502Laboratories:(a) work positions at which instruments are read or hazardous substances are handled, if errors in such reading or handling may be hazardous to the health or safety of an employee800(b) work positions at which close or prolonged attention is given to laboratory work500(c) other areas503Workshops and garages:(a) work positions at which fine or medium bench, machine or repair work is performed500(b) work positions at which rough bench, machine or repair work is performed300(c) other areas504Process areas:(a) work positions in major control rooms or rooms with dial displays at which tasks essential to the control of equipment or machinery that may be hazardous to the safety of employees are performed800(b) work positions at which a hazardous substance is used, stored or handled500(c) work positions at which gauges and meters that are not self-illuminating are located50(d) other areas205Loading platforms and warehouses:(a) work positions at which packages or goods are checked or sorted150(b) work positions at which loading or unloading work is frequently performed1006Storage areas:(a) areas in which there is a high level of activity50(b) other areas207Derricks, drill floors and moon pools:(a) work positions at which there is a high level of activity100(b) other areas208Entrances, exits, elevators, corridors, aisles and stairways:(a) areas in which there is a high level of activity or where there is a high frequency of traffic100(b) other areas509Medical rooms:(a) work positions at which first aid or medical care is rendered or examinations are conducted or at which other tasks essential to the health or safety of an employee are performed1000(b) other areas50010Food preparation areas:(a) work positions at which prolonged cutting or preparation tasks are performed1000(b) other areas30011Dining areas and recreation areas20012Sleeping quarters10013Washrooms and showers20014Boiler, engine, ballast control and generator rooms20015Rooms in which principal heating, ventilation or air-conditioning equipment is installed7016Emergency shower facilities, emergency equipment locations, muster stations, temporary refuge areas and lifeboat and life raft locations50
Read the Canada–Newfoundland and Labrador Offshore Area Occupational Health and Safety Regulations on the Justice Laws Website ↗
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.