Off-road Compression-Ignition (Mobile and Stationary) and Large Spark-Ignition Engine Emission Regulations, SOR/2020-258
Section 16
Backup or emergency stationary engines
Cite as Off-road Compression-Ignition (Mobile and Stationary) and Large Spark-Ignition Engine Emission Regulations, SOR/2020-258, s. 16 · current to July 24, 2025 · regulation last amended October 3, 2022
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) A stationary compression-ignition engine that is intended to provide electrical power or mechanical work during a power outage may, instead of conforming to the emission standards referred to in subsection 11(1), conform to those set out in sections 4202(a)(1)(ii), (a)(2), (b)(2), (e)(2) and (4) and (f)(1) and (2), subpart IIII, of CFR 60.
(2) A stationary compression-ignition engine that is a fire-pump engine may, instead of conforming to the emission standards referred to in subsection 11(1), conform to those set out in section 4202(d), subpart IIII, of CFR 60.
(3) A stationary compression-ignition engine that is to be used in a remote location may, instead of conforming to the emission standards set out in subsection 11(1), conform to those set out in section 4201(f), subpart IIII, of CFR 60 or those set out in sections 4202(a)(1)(ii), (a)(2), (b)(2), (e)(2) and (4) and (f)(1) and (2), subpart IIII, of CFR 60.
(4) The standards referred to in subsections (1) to (3) apply for the useful life of the engine referred to in subsection 11(3).
Read the Off-road Compression-Ignition (Mobile and Stationary) and Large Spark-Ignition Engine Emission Regulations on the Justice Laws Website ↗
Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.