Any stairs that are used to board or disembark from a train, and any interior stairs on a train, must
(a) meet the requirements set out in clauses 5.4.1 and 5.4.2 of CSA B651-18;
(b) have handrails that
(i) are located on both sides of the stairs,
(ii) are located at a uniform height of 860 mm to 920 mm, measured vertically from the leading edge of the tread, and
(iii) meet the requirements set out in clause 5.3.1 of CSA B651-18; and
(c) have tactile attention indicator surfaces that
(i) meet the meet the requirements set out in clauses 4.3.5.2(a) and (b), 4.3.5.3.1 and 4.3.5.3.4 of CSA B651-18,
(ii) are located at the top of the stairs, and
(iii) commence one tread length before the top of the stairs, extend the full width of the stairs and measure from 600 mm to 650 mm in length.