Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector), SOR/2018-66

Section 37

Pneumatic controllers — bleed rate

Cite as Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector), SOR/2018-66, s. 37 · current to December 29, 2025 · regulation last amended December 12, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) A pneumatic controller at an upstream oil and gas facility must not operate using hydrocarbon gas, other than propane, unless (a) it is operated at an operational setting such that its bleed rate for that operational setting is less than or equal to 0.17 standard m3/h according to the manufacturer’s operating manual or according to a written demonstration, with supporting documents, made by the operator for the facility; or (b) the hydrocarbon emissions from it are captured and routed to hydrocarbon gas conservation equipment or hydrocarbon gas destruction equipment. (2) Despite paragraph (1)(a), a pneumatic controller at an upstream oil and gas facility may operate using hydrocarbon gas, other than propane, at an operational setting such that its bleed rate for that operational setting is more than 0.17 standard m3/h if the operator for the facility has a written record, with supporting documents, that demonstrates that the pneumatic controller must operate at that operational setting because of the need for the pneumatic controller to have a sufficient response time to control a process in the facility’s production activities.
Read the Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector) on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.