Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector), SOR/2018-66
Section 30
Obligation to inspect
Cite as Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector), SOR/2018-66, s. 30 · current to December 29, 2025 · regulation last amended December 12, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) An equipment component at an upstream oil and gas facility must be inspected, during the periods referred to in subsection (3), for the release of hydrocarbons by means of an eligible leak detection instrument.
(2) The following leak detection instruments are eligible:
(a) a portable monitoring instrument if it
(i) meets the specifications set out in Section 6 of EPA Method 21,
(ii) is operated in accordance with the requirements of Section 8.3 of EPA Method 21 to the extent that those requirements are consistent with its manufacturer’s recommendations,
(iii) is calibrated in accordance with Sections 7, 8.1, 8.2 and 10 of EPA Method 21 before it is used, for each day on which it is used, and
(iv) undergoes a calibration drift assessment after its last use on each of those days in accordance with the requirements set out in Section 60.485a(b)(2) of Subpart VVa, entitled Standards of Performance for Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry for which Construction, Reconstruction, or Modification Commenced After November 7, 2006, in Part 60 of Title 40, Chapter I of the Code of Federal Regulations of the United States; and
(b) an optical gas-imaging instrument if it is capable of imaging gas that is
(i) in the spectral range for the compound of highest concentration in the hydrocarbon gas to be measured,
(ii) half methane and half propane at a total concentration of at most 500 ppmv and at a flow rate of at least 60 g/h leaking from an orifice that is 0.635 cm in diameter, and
(iii) at the viewing distance determined in accordance with the requirements of the alternative work practice of the Environmental Protection Agency of the United States set out in Sections 60.18(h)(7)(i)(2)(i) to (v) of Section 60.18, entitled General control device and work practice requirements, in Part 60 of Title 40, Chapter I of the Code of Federal Regulations of the United States.
(3) The period for inspections is as follows:
(a) for the first inspection, on or before the later of May 1, 2020 and the day that occurs 60 days after the day on which production at the facility first began; and
(b) for subsequent inspections, at least three times per year and at least 60 days after a previous inspection.
(4) An eligible leak detection instrument must be operated and maintained in accordance with the recommendations, if any, of its manufacturer.
(5) The inspection must be conducted by an individual who, not more than five years before the inspection, has received training in
(a) the operation and maintenance, in accordance with subsection (4), of eligible leak detection instruments; and
(b) the calibration requirements set out in subparagraphs (2)(a)(iii) and (iv), if an eligible portable monitoring instrument is used.
Read the Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector) on the Justice Laws Website ↗
Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.