Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector), SOR/2018-66
Section 18
Corrective action
Cite as Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector), SOR/2018-66, s. 18 · current to December 29, 2025 · regulation last amended December 12, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) If the flow rate of emissions of hydrocarbon gas released from vents referred to in paragraph 14(b) of a compressor, measured in accordance with subsection 16(2), is greater than the applicable flow rate limit set out in subsection (2) or (3) or if the alarm referred to in paragraph 17(c) is triggered, corrective action must be taken to reduce that flow rate to below or equal to that limit, as demonstrated by a remeasurement that results,
(a) when a flow meter is used for the remeasurement, in a reading that is below or equal to that limit; or
(b) when a continuous monitoring device is used for the remeasurement, in the absence of an alarm when the compressor resumes operation following the taking of the corrective action.
(2) For emissions that are from the seals of a centrifugal compressor, the flow rate limit is
(a) if the compressor is installed on or after January 1, 2023, 0.14 standard m3/min; and
(b) if the compressor is installed before January 1, 2023 and has a rated brake power of
(i) greater than or equal to 5 MW, 0.68 standard m3/min, and
(ii) less than 5 MW, 0.34 standard m3/min.
(3) For emissions that are from the rod packings and distance pieces of a reciprocating compressor, the flow rate limit is
(a) if the compressor is installed on or after January 1, 2023, the product of 0.001 standard m3/min and the number of pressurized cylinders that the compressor has; and
(b) if the compressor is installed before January 1, 2023, the product of 0.023 standard m3/min and the number of those pressurized cylinders.
(4) The remeasurement referred to in paragraph (1)(a) or (b) must be taken in accordance with section 15 on or before the later of
(a) the 90th day after the day on which, as the case may be, the most recent measurement is taken under subsection 16(3) or the alarm referred to in paragraph 17(c) is triggered, and
(b) if the estimated volume of hydrocarbon gas, expressed in standard m3, that would, beginning from the day on which the applicable day described in paragraph (a), be emitted until that next planned shutdown if no corrective action were taken is equal to or less than the volume of hydrocarbon gas, expressed in standard m3, that would be emitted due to the purging of hydrocarbon gas in order to take the corrective action,
(i) the day on which the compressor begins to operate after the next planned shutdown, in the case of a centrifugal compressor, and
(ii) the day on which the compressor is first pressurized after the next planned shutdown, in the case of a reciprocating compressor.
(5) The estimated volume of hydrocarbon gas must be based on the most recent flow rate of emissions of hydrocarbon gas released from vents referred to in paragraph 14(b) of the compressor, as determined by a flow meter or a continuous monitoring system in accordance with section 15.
Read the Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector) on the Justice Laws Website ↗
Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.