The text

(1) Subject to section 15, the quantity of CO2 emissions resulting from the combustion of fossil fuels in a unit combusting biomass in a calendar year that is measured using a CEMS must be determined in accordance with the following formula:Eu × (Vff / VT) – EswhereEuis the quantity of CO2 emissions, expressed in tonnes, from the unit, “u”, during the calendar year from the combustion of fuel, as measured by the CEMS, and calculated in accordance with sections 7.1 to 7.7 of the Reference Method;Vffis the volume of CO2 emissions released from combustion of fossil fuel in the unit during the calendar year, expressed in standard m3 and determined in accordance with the following formula:The formula is the sum of the products resulting from the multiplication of Qi, Fc,i and HHVi for each fossil fuel type “i”.whereQiis the quantity of fossil fuel type “i” combusted in the unit during the calendar year, determined(a) for a gaseous fuel, in the same manner used in the determination of Vf in the formula set out in paragraph 18(1)(a) and expressed in standard m3,(b) for a liquid fuel, in the same manner used in the determination of Vf in the formula set out in paragraph 18(1)(b) and expressed in kL, and(c) for a solid fuel, in the same manner used in the determination of Mf in the formula set out in paragraph 18(1)(c) and expressed in tonnes,iis the ith fossil fuel type combusted in the unit during the calendar year, where “i” goes from the number 1 to n and where n is the number of fossil fuels so combusted,Fc,iis the fuel-specific carbon-based F-factor for each fossil fuel type “i” — being the factor set out in Appendix A of the Reference Method, or for fuels not listed, the one determined in accordance with that Appendix — corrected to be expressed in standard m3 of CO2/GJ, andHHViis the higher heating value for each fossil fuel type “i” that is measured in accordance with subsection (2), or in the absence of a measured higher heating value, the default higher heating value, set out in column 2 of Schedule 2, for the fuel type, as set out in column 1;VTis the volume of CO2 emissions released from combustion of fuel — fossil fuel and biomass — in the unit during the calendar year determined in accordance with the following formula:The summation of the products of 0.01, CO2w,t and Qw,t for each hour “t”.wheretis the tth hour, where “t” goes from the number 1 to n and where n is the total number of hours during which the unit generated electricity in the calendar year,CO2w,tis the average concentration of CO2 in relation to all gases in the stack emitted from the combustion of fuel in the unit during each hour “t”, during which the unit generated electricity in the calendar year — or, if applicable, a calculation made in accordance with section 7.4 of the Reference Method of that average concentration of CO2 based on a measurement of the concentration of oxygen (O2) in those gases in the stack — expressed as a percentage on a wet basis, andQw,tis the average volumetric flow during that hour, measured on a wet basis by the stack gas volumetric flow monitor, expressed in standard m3; andEsis the quantity of CO2 emissions, expressed in tonnes, that is released from the use of sorbent to control the emission of sulphur dioxide from the unit during the calendar year, determined in accordance with the following formula:S × R × (44/MMs)whereSis the quantity of sorbent material, such as calcium carbonate (CaCO3), expressed in tonnes,Ris the stoichiometric ratio, on a mole fraction basis, of CO2 released on usage of one mole of sorbent material, which is equal to 1 if the sorbent material is CaCO3, andMMsis the molecular mass of the sorbent material, which is equal to 100 if the sorbent material is CaCO3. (2) The higher heating value of a fuel is to be measured (a) for a gaseous fuel, (i) in accordance with whichever of the following standards that applies: (A) ASTM D1826 - 94(2017), entitled Standard Test Method for Calorific (Heating) Value of Gases in Natural Gas Range by Continuous Recording Calorimeter, (B) ASTM D3588 - 98(2017), entitled Standard Practice for Calculating Heat Value, Compressibility Factor, and Relative Density of Gaseous Fuels, (C) ASTM D4891 - 13, entitled Standard Test Method for Heating Value of Gases in Natural Gas and Flare Gases Range by Stoichiometric Combustion, (D) Gas Processors Association Standard 2172 - 14, entitled Calculation of Gross Heating Value, Relative Density, Compressibility and Theoretical Hydrocarbon Liquid Content for Natural Gas Mixtures for Custody Transfer, and (E) Gas Processors Association standard 2261 - 13, entitled Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography, or (ii) by means of a direct measuring device that measures the higher heating value of the fuel, but if the measuring device provides only lower heating values, those lower heating values must be converted to higher heating values; and (b) for a liquid fuel that is (i) an oil or a liquid fuel derived from waste, in accordance with (A) ASTM D240 - 17, entitled Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter, or (B) ASTM D4809 - 13, entitled Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter (Precision Method), and (ii) any other liquid fuel type, in accordance with an applicable ASTM standard for the measurement of the higher heating value of the fuel type or, if no such ASTM standard applies, in accordance with an applicable internationally recognized method.
Read the Regulations Limiting Carbon Dioxide Emissions from Natural Gas-fired Generation of Electricity on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.