Quantity of energy

Cite as Regulations Limiting Carbon Dioxide Emissions from Natural Gas-fired Generation of Electricity, SOR/2018-261, s. 11 · current to July 24, 2025 · regulation last amended January 1, 2019

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The quantity of energy produced by a given unit is determined by the formulaG + (0.75 × Hpnet)whereGis(a) the gross quantity of electricity generated by the unit in the calendar year expressed in GWh, as measured at the electrical terminals of the generators of the unit using meters that comply with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations, or(b) in the case of a hybrid configuration – when the unit is either a combustion engine unit that shares a steam turbine with a boiler unit or a boiler unit that shares a steam turbine with a combustion engine unit – the quantity of electricity generated by the given unit in the calendar year expressed in GWh, determined by the formula in subsection (2); andHpnetis the net quantity of useful thermal energy produced by the unit in a calendar year, expressed in GWh, determined by the formula in subsection (3). (2) The quantity of electricity generated by a given unit is determined by the formulaGce + Gs – GextwhereGceis the gross quantity of electricity that is generated by the generators of the combustion engines in a combustion engine unit that shares a steam turbine with a boiler unit, in the calendar year, expressed in GWh, as measured at the electrical terminals of the generators of the combustion engines using meters that comply with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations, if the given unit for which the electricity is being quantified is a combustion engine unit, or equal to zero, if the given unit for which the electricity is being quantified is a boiler unit;Gsis the gross quantity of electricity that is generated by the generators of the shared steam turbine in the calendar year, expressed in GWh, as measured at the electrical terminals of the generators of the shared steam turbine using meters that comply with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations; andGextis the quantity of electricity that is generated by the unit other than the given unit for which the electricity is being quantified, in the calendar year, expressed in GWh and that is determined by the formulaGext is equal to Gs, multiplied by the summation for all time periods “t” of a quotient where the numerator is the summation of the products of hext_j and Mext_j for each heat stream “j”, and the denominator is the summation of the products of hext_j and Mext_j for each heat stream “j” plus the summation of the products of hint_k and Mint_k for each heat stream “k”.whereGsis the gross quantity of electricity that is generated by the generators of the shared steam turbine in the calendar year, expressed in GWh, as measured at the electrical terminals of the generators of the shared steam turbine using meters that comply with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations,tis the tth hour, where “t” goes from the number 1 to x and where x is the total number of hours during which the generators of the shared steam turbine generated electricity in the calendar year,jis the jth external heat stream, originating from the other unit where “j” goes from the number 1 to m and where m is the total number of external heat streams that contributed to the electricity generated by the generators of the shared steam turbine of the unit,hext_jis the average specific enthalpy of the jth external heat stream, originating from the other unit that contributed to the electricity generated by the generators of the shared steam turbine, expressed in GJ/tonne, during period “t” and must be based on the measurement of the temperature and pressure of that heat stream and determined using a continuous measuring device,Mext_jis the mass flow of the jth external heat stream originating from the other unit that contributed to the electricity generated by the generators of the shared steam turbine, expressed in tonnes, during period “t”, determined using a continuous measuring device,kis the kth internal heat stream originating from the given unit, where “k” goes from the number 1 to l and where l is the total number of heat streams that originated from the combustion of fuel in the unit and that contributed to the electricity generated by the generators of the shared steam turbine,hint_kis the average specific enthalpy of the kth internal heat stream originating from the given unit and having contributed to the electricity generated by the generators of the shared steam turbine, expressed in GJ/tonne, during period “t” and must be based on the measurement of the temperature and pressure of that heat stream and determined using a continuous measuring device, andMint_kis the mass flow of the kth internal heat stream originating from the given unit that contributed to the electricity generated by the generators of the shared steam turbine, expressed in tonnes, during period “t”, determined using a continuous measuring device. (3) In the case of a unit that simultaneously generates electricity and produces useful thermal energy from the fuel combusted by a combustion engine or boiler, as the case may be, the net quantity of useful thermal energy produced by the unit in a calendar year, expressed in GWh, is determined by the formulaThe summation of the products of hout_i and Mout_i for each heat stream “i” minus the summation of the products of hin_j and Min_j for each heat stream “j”, summed for all time periods and then multiplied by the quotient of 1 over 3600 GJ per GWh.wheretis the tth hour, where “t” goes from the number 1 to x and where x is the total number of hours during which the unit produced useful thermal energy in the calendar year;iis the ith heat stream exiting the unit, where “i” goes from the number 1 to n and where n is the total number of heat streams exiting the unit;hout_iis the average specific enthalpy of the ith heat stream exiting the unit, expressed in GJ/tonne, during period “t” and must be based on the measurement of the temperature and pressure of that heat stream and determined using a continuous measuring device;Mout_iis the mass flow of the ith heat stream exiting the unit, expressed in tonnes, during period “t”, determined using a continuous measuring device;jis the jth heat stream — other than condensate return — entering the unit, where “j” goes from the number 1 to m and where m is the total number of heat streams entering the unit;hin_jis the average specific enthalpy of the jth heat stream — other than condensate return — entering the unit, expressed in GJ/tonne, during period “t” and must be based on the measurement of the temperature and pressure of that heat stream and determined using a continuous measuring device; andMin_jis the mass flow of the jth heat stream — other than condensate return — entering the unit, expressed in tonnes, during period “t”, determined using a continuous measuring device.
Read the Regulations Limiting Carbon Dioxide Emissions from Natural Gas-fired Generation of Electricity on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.