(1) Oil fuel tanks on Category A and B vessels that were constructed on or after January 1, 2017 and have an aggregate oil fuel capacity of less than 600 m3, other than oil fuel tanks with a maximum individual capacity of 30 m3 or less, must be separated from the outer shell of the vessel by a distance of at least 0.76 m.
(2) Cargo tanks used to carry oil on Category A and B vessels constructed on or after January 1, 2017, other than oil tankers, must be separated from the outer shell of the vessel by a distance of at least 0.76 m.
(3) Subject to subsection (4), cargo tanks on Category A and B oil tankers constructed on or after January 1, 2017, that are of less than 5 000 metric tonnes deadweight, must be protected the length of the tank with
(a) double bottom tanks or double bottom spaces in accordance with the applicable requirements of regulation 19.6.1 of Annex I to MARPOL; and
(b) wing tanks or wing spaces arranged in accordance with the applicable requirements of regulation 19.3.1 of Annex I to MARPOL and complying with the applicable distance requirements in accordance with regulation 19.6.2 of Annex I to MARPOL.
(4) An oil tanker that is a Canadian vessel of less than 5 000 metric tonnes deadweight that does not have mechanical means of propulsion and engages only on voyages in waters under Canadian jurisdiction within 40 nautical miles from the nearest land is not required to comply with paragraph (3)(a) if the height of its double bottom is, in no location, less than the width calculated for its wing tanks in accordance with the formula in regulation 19.6.2 of Annex I to MARPOL.
(5) Oil residue tanks and oily bilge water holding tanks on Category A and B vessels constructed on or after January 1, 2017, other than oil fuel tanks with a maximum individual capacity of 30 m3 or less, must be separated from the outer shell of the vessel by a distance of at least 0.76 m.
(6) Subsections (1) to (3) and (5) do not apply to vessels referred to in paragraph 46(2)(b) of the Vessel Pollution and Dangerous Chemicals Regulations.