Vessel Fire Safety Regulations, SOR/2017-14
Section 212
Cite as Vessel Fire Safety Regulations, SOR/2017-14, s. 212 · current to July 24, 2025 · regulation last amended November 23, 2022
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) The following doors and other closures of openings must have fire-resistant properties equivalent to those of the class divisions of the structures in which they are fitted:
(a) doors in an engine or boiler casing;
(b) doors and other closures of openings in a deck or bulkhead referred to in sections 205 to 207; and
(c) doors in an enclosure referred to in subsection 210(2) or (3).
(2) The doors to machinery spaces of category A must be self-closing and reasonably gastight.
(3) A door required by subsection (1) that is in an “A” class division must be reasonably gastight.
(4) Every door in an “A” class division must overlap the door frame, and allow for a gap, between the edges of the door and the top, bottom and sides of the door frame, that is the minimum needed to open and close the door.
(5) A grille or louvre must not be fitted in a door required by subsection (1) that is in an “A” class division.
(6) A hose port that is fitted in a door required by subsection (1) that is in an “A” class division must
(a) be self-closing;
(b) be constructed of material that has fire-resistance that is at least equivalent to the door in which it is fitted;
(c) have a clear opening that has a width and length of 150 mm when the door is closed; and
(d) be inset into the lower edge of the door, either on the side opposite the door hinges or, in the case of a sliding door, on the side nearest the opening.
(7) Every door required by subsection (1) that is in an “A” or “B” class division must be fitted with a thin metal identification plate that
(a) has clearly stamped on it the door manufacturer’s name, the “A” or “B” class rating, the type approval certificate number and the number of the drawing to which the door has been manufactured; and
(b) is screwed or riveted to either of the vertical edges of the door panel.
Read the Vessel Fire Safety Regulations on the Justice Laws Website ↗
Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.