Vessel Fire Safety Regulations, SOR/2017-14
Section 128
Cite as Vessel Fire Safety Regulations, SOR/2017-14, s. 128 · current to July 24, 2025 · regulation last amended November 23, 2022
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) In addition to being provided with the hydrants required by regulation 10.2.1.5.1,
(a) a passenger vessel on a near coastal voyage, Class 1, or an unlimited voyage and a vessel of 500 gross tonnage or more must be provided, in each machinery space of category A, with one hydrant on the port side and one hydrant on the starboard side; and
(b) any other vessel of less than 500 gross tonnage must be provided with one hydrant in each machinery space of category A.
(2) A fire hose and nozzle must be fitted on each hydrant required by subsection (1).
(3) If the size or configuration of a machinery space of category A would render a hydrant required by subsection (1) ineffective, the hydrant must be located near the main access to the space.
(4) In addition to being provided with the hydrants required by regulation 10.2.1.5.1, a cargo vessel of 2 000 gross tonnage or more must
(a) be provided with a hydrant in the shaft tunnel, if any, adjacent to the engine room watertight door; and
(b) meet the requirements of regulation 10.2.1.5.2.2.
Read the Vessel Fire Safety Regulations on the Justice Laws Website ↗
Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.