(1) A railway company must not place into service a locomotive unless, when tested in accordance with section 8, the locomotive conforms to the applicable exhaust emission standards set out in Tables 1 and 2 to section 1033.101 of the CFR and in paragraph 1033.101(f)(1) of the CFR.
(2) Despite subsection (1), when tested in accordance with section 8, the locomotive placed into service by the railway company may conform to the alternate carbon monoxide and particulate matter emissions standards set out in paragraph 1033.101(i) of the CFR instead of the applicable carbon monoxide and particulate matter emission standards set out in Tables 1 and 2 to section 1033.101 of the CFR.
(3) Subsections (1) and (2) do not apply in respect of a locomotive that is covered by an EPA certificate and that is affixed with the EPA locomotive label and EPA locomotive engine label that are set out in section 1033.135 of the CFR.
(4) If a locomotive is not covered by an EPA certificate or is covered by an EPA certificate but one that does not set out family emission limits, a railway company must not operate the locomotive after the locomotive has been placed into service unless, when tested in accordance with section 8, the locomotive conforms to the applicable exhaust emission standards set out in Tables 1 and 2 to section 1033.101 of the CFR and in paragraph 1033.101(f)(1) of the CFR.
(5) If a locomotive is covered by an EPA certificate that sets out family emission limits, a railway company must not operate the locomotive after the locomotive has been placed into service unless, when tested in accordance with section 8, the locomotive conforms to
(a) the applicable exhaust emission standards set out in Tables 1 and 2 to section 1033.101 of the CFR and in paragraph 1033.101(f)(1) of the CFR for which there are no family emission limits; and
(b) the family emission limits.
(6) Despite subsection (4) or (5), when tested in accordance with section 8, a locomotive referred to in subsection (4) or (5) may conform to the alternate carbon monoxide and particulate matter emissions standards set out in paragraph 1033.101(i) of the CFR instead of the applicable carbon monoxide and particulate matter emission standards set out in Tables 1 and 2 to section 1033.101 of the CFR.
(7) For the purposes of this section, footnotes d and e to Table 1 to section 1033.101 of the CFR and footnotes b and c to Table 2 to that section do not apply.
Read the Locomotive Emissions Regulations on the Justice Laws Website ↗