Energy Efficiency Regulations, 2016, SOR/2016-311
Section 756
Information
Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 756 · current to April 28, 2026 · regulation last amended October 9, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a small electric motor:
(a) its average full load efficiency;
(b) its type, namely, capacitor-start capacitor-run, capacitor-start induction-run or polyphase; and
(c) if the motor is one for which a unique motor identifier has not been provided under paragraph 5(1)(c), its nominal output power expressed in kilowatts (horsepower) and the number of poles.
(2) The information must be collected in accordance with one of the following standards:
(a) if the motor is polyphase and has a nominal output power ≥ 0.18 kW (0.25 horsepower) but ≤ 0.75 kW (1 horsepower), CSA C747-09, IEEE 112 (Test Method A) or IEC 60034-2-1 (Test Method 2-1-1A);
(b) if the motor is polyphase and has a nominal output power > 0.75 kW (1 horsepower) but ≤ 2.2 kW (3 horsepower), CSA C390-10, IEEE 112 (Test Method B) or IEC 60034-2-1 (Test Method 2-1-1B); or
(c) if the motor is capacitor-start capacitor-run or capacitor-start induction-run, CSA C747-09, IEEE 114-2010 or IEC 60034-2-1 (Test Method 2-1-1A).
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗
Made under Energy Efficiency Act, S.C. 1992, c. 36.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.