Energy Efficiency Regulations, 2016, SOR/2016-311
Section 666
Energy efficiency standards
Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 666 · current to April 28, 2026 · regulation last amended October 9, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) The energy efficiency standards set out in column 2 of the table to this section apply to walk-in refrigeration systems described in column 1 that are manufactured during the periods set out in column 3.
(2) A walk-in refrigeration system complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix C that are applicable to a walk-in refrigeration system as defined in section 657.TABLEItemColumn 1Column 2Column 3Energy-using ProductEnergy Efficiency StandardPeriod of Manufacture1Walk-in cooler dedicated condensing refrigeration systems for use indoorsAnnual walk-in energy factor ≥ 1.644 W-h/W-h (5.61 Btu/W-h)On or after January 1, 20202Walk-in cooler dedicated condensing refrigeration systems for use outdoorsAnnual walk-in energy factor ≥ 2.227 W-h/W-h (7.60 Btu/W-h)On or after January 1, 20203Walk-in freezer dedicated condensing refrigeration systems for use indoors with a net refrigeration capacity of < 1900 W (6,500 Btu/h)Annual walk-in energy factor ≥ 9.091 x 10-5 x qnet + 0.530 W-h/W-h (9.091 x 10-5 x qnet+ 1.81 Btu/W-h)On or after July 10, 20204Walk-in freezer dedicated condensing refrigeration systems for use indoors with a net refrigeration capacity of ≥ 1900 W (6,500 Btu/h)Annual walk-in energy factor ≥ 0.703 W-h/W-h (2.40 Btu/W-h)On or after July 10, 20205Walk-in freezer dedicated condensing refrigeration system for use outdoors with a net refrigeration capacity of < 1900 W (6,500 Btu/h)Annual walk-in energy factor ≥ 6.522 x 10-5 x qnet + 0.800 W-h/W-h (6.522 x 10-5 x qnet + 2.73 Btu/W-h)On or after July 10, 20206Walk-in freezer dedicated condensing refrigeration systems for use outdoors with a net refrigeration capacity of ≥ 1900 W (6,500 Btu/h)Annual walk-in energy factor ≥ 0.923 W-h/W-h (3.15 Btu/W-h)On or after July 10, 20207Walk-in cooler unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V ACAnnual walk-in energy factor ≥ 2.638 W-h/W-h (9.00 Btu/W-h)On or after July 10, 20208Walk-in freezer unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V AC and with a net refrigeration capacity of < 4540 W (15,500 Btu/h)Annual walk-in energy factor ≥ 1.575 x 10-5 x qnet + 1.146 W-h/W-h (1.575 x 10-5 x qnet + 3.91 Btu/W-h)On or after July 10, 20209Walk-in freezer unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V AC and with a net refrigeration capacity of ≥ 4540 W (15,500 Btu/h)Annual walk-in energy factor ≥ 1.216 W-h/W-h (4.15 Btu/W-h)On or after July 10, 2020
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗
Made under Energy Efficiency Act, S.C. 1992, c. 36.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.