Energy Efficiency Regulations, 2016, SOR/2016-311
Section 372
Energy efficiency standards
Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 372 · current to April 28, 2026 · regulation last amended October 9, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) The energy efficiency standards set out in column 3 of the table to this section apply to an electric water heater described in column 1 that is manufactured during the periods set out in column 4.
(2) An electric water heater described in column 1 complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an electric water heater as defined in subsection 369(1).TABLEItemColumn 1Column 2Column 3Column 4Energy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Household electric water heaters that have a bottom inlet and a Vr of ≥ 50 L (13.2 US gallons) but ≤ 270 L (71.3 US gallons)CSA C191-04Standby loss, in W, ≤ 40 + 0.2 VrOn or after February 3, 1995 and before May 6, 20292Household electric water heaters that have a bottom inlet and a Vr of ≥ 50 L (13.2 US gallons) but < 76 L (20 US gallons)CSA C191-04Standby loss, in W, ≤ 40 + 0.2 VrOn or after May 6, 20293Household electric water heaters that have a bottom inlet and a Vr of > 270 L (71.3 US gallons) but ≤ 454 L (120 US gallons)CSA C191-04Standby loss, in W, ≤ 0.472 Vr − 33.5On or after February 3, 1995 and before May 6, 20294Household electric water heaters that have a top inlet and a Vr of ≥ 50 L (13.2 US gallons) but ≤ 270 L (71.3 US gallons)CSA C191-04Standby loss, in W, ≤ 35 + 0.2 VrOn or after February 3, 1995 and before May 6, 20295Household electric water heaters that have a top inlet and a Vr of ≥ 50 L (13.2 US gallons) but < 76 L (20 US gallons)CSA C191-04Standby loss, in W, ≤ 35 + 0.2 VrOn or after May 6, 20296Household electric water heaters that have a top inlet and a Vr of > 270 L (71.3 US gallons) but ≤ 454 L (120 US gallons)CSA C191-04Standby loss, in W, ≤ 0.472 Vr − 38.5On or after February 3, 1995 and before May 6, 20297Household electric water heaters that have a Veff of ≥ 76 L (20 US gallons) but ≤ 208 L (55 US gallons)10 C.F.R. Appendix EMust have at least one of the following:(a) uniform energy factor of ≥ 0.8808 − 0.000211 Veff, if draw pattern is very-small-usage;(b) uniform energy factor of ≥ 0.9254 − 0.000079 Veff, if draw pattern is low-usage;(c) uniform energy factor ≥ 0.9307 − 0.000053 Veff, if draw pattern is medium-usage; or(d) uniform energy factor ≥ 0.9349 − 0.000026 Veff, if draw pattern is high-usage.On or after May 6, 20298Household electric water heaters that have a Veff of ˃ 208 L (55 US gallons) but ≤ 454 L (120 US gallons)10 C.F.R. Appendix EUniform energy factor ≥ 0.9349 − 0.000026 VeffOn or after May 6, 20299Commercial electric water heaters10 C.F.R. Appendix BStandby loss, in %/hr ≤ 0.3 + 102.2/VsOn or after January 1, 2020
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗
Made under Energy Efficiency Act, S.C. 1992, c. 36.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.