Energy Efficiency Regulations, 2016, SOR/2016-311

Section 322

Information

Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 322 · current to April 28, 2026 · regulation last amended October 9, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired boiler described in column 1.TABLEColumn 1Column 2Column 3ItemEnergy-using ProductTesting StandardInformation1Household oil-fired boilers manufactured on or after December 31, 1998 and before September 1, 2010CSA B212(a) input rate, in kW (Btu/h); and(b) seasonal energy utilization efficiency.2Household oil-fired boilers manufactured on or after September 1, 2010 and before January 15, 2021ASHRAE 103 for information set out in paragraphs (a) to (f)(a) type of central heating system for which product is intended;(b) maximum heat input and output nominal capacities, in kW (Btu/h);(c) power burner’s PE;(d) water pump’s BE;(e) average annual electrical energy consumption (EAE), in kWh;(f) annual fuel utilization efficiency; and(g) if product is manufactured on or after September 1, 2012,(i) information that indicates whether product has tankless domestic water heating coils, and(ii) type of automatic water temperature adjustment device product has, if any.3Household oil-fired boilers manufactured on or after January 15, 2021CSA P.2 for information set out in paragraphs (a) to (e)(a) type of central heating system for which product is intended;(b) maximum heat input and output nominal capacities, in kW (Btu/h);(c) annual fuel utilization efficiency;(d) standby power, in W;(e) off-mode power, in W;(f) information that indicates whether product has tankless domestic water heating coils; and(g) type of automatic water temperature adjustment device product has, if any.4Commercial oil-fired boilers manufactured on or after January 1, 202510 C.F.R. Appendix A(a) type of central heating system for which product is intended;(b) maximum heat input nominal capacity, in kW (Btu/h); and(c) thermal efficiency or, if product has an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and is intended for hot water systems, combustion efficiency.
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗

Made under Energy Efficiency Act, S.C. 1992, c. 36.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.