Energy Efficiency Regulations, 2016, SOR/2016-311
Section 317
Energy efficiency standards — household
Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 317 · current to April 28, 2026 · regulation last amended October 9, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to household gas boilers described in column 1 that are manufactured during the periods set out in column 4.
(2) A household gas boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to a gas boiler as defined in section 315.
(3) The energy efficiency standards set out in column 2 of Table 2 to this section apply to commercial gas boilers described in column 1 that are manufactured on or after January 1, 2025.
(4) A commercial gas boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to a gas boiler as defined in section 315.TABLE 1ItemColumn 1Column 2Column 3Column 4Energy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Household gas boilers that are intended for low pressure steam systemsCGA P.2Annual fuel utilization efficiency ≥ 75%On or after December 31, 1998 and before September 1, 20102Household gas boilers that are intended for low pressure steam systemsCSA P.2 for annual fuel utilization efficiencyAnnual fuel utilization efficiency ≥ 80%No continuously burning pilot lightOn or after September 1, 2010 and before January 15, 20212.1Household gas boilers that are intended for low pressure steam systemsCSA P.2 for annual fuel utilization efficiency, standby power and off-mode powerAnnual fuel utilization efficiency ≥ 82%No continuously burning pilot lightStandby power ≤ 8 WOff-mode power ≤ 8 WOn or after January 15, 20213Household gas boilers that are intended for hot water systemsCGA P.2Annual fuel utilization efficiency ≥ 80%On or after December 31, 1998 and before September 1, 20104Household gas boilers that are intended for hot water systemsCSA P.2 for annual fuel utilization efficiencyAnnual fuel utilization efficiency ≥ 82%No continuously burning pilot lightOn or after September 1, 2010 and before September 1, 20125Household gas boilers that are intended for hot water systems and have tankless domestic water heating coilsCSA P.2 for annual fuel utilization efficiencyAnnual fuel utilization efficiency ≥ 82%No continuously burning pilot lightOn or after September 1, 2012 and before July 1, 20235.1Household gas boilers that are intended for hot water systems and have tankless domestic water heating coilsCSA P.2 for annual fuel utilization efficiency, standby power and off-mode powerAnnual fuel utilization efficiency ≥ 90%No continuously burning pilot lightStandby power ≤ 9 WOff-mode power ≤ 9 WOn or after July 1, 20236Household gas boilers that are intended for hot water systems and do not have tankless domestic water heating coilsCSA P.2 for annual fuel utilization efficiencyAnnual fuel utilization efficiency ≥ 82%No continuously burning pilot lightEquipped with automatic water temperature adjustment device and not operable without the deviceOn or after September 1, 2012 and before July 1, 20237Household gas boilers that are intended for hot water systems and do not have tankless domestic water heating coilsCSA P.2 for annual fuel utilization efficiency, standby power and off-mode powerAnnual fuel utilization efficiency ≥ 90%No continuously burning pilot lightEquipped with automatic water temperature adjustment device and not operable without the deviceStandby power ≤ 9 WOff-mode power ≤ 9 WOn or after July 1, 2023TABLE 2ItemColumn 1Column 2Energy-using ProductEnergy Efficiency Standard1Commercial gas boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for hot water systemsThermal efficiency ≥ 90%2Commercial gas boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for hot water systemsCombustion efficiency ≥ 90%3Commercial gas boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for low pressure steam systemsThermal efficiency ≥ 81%4Commercial gas boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for low pressure steam systemsThermal efficiency ≥ 82%
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗
Made under Energy Efficiency Act, S.C. 1992, c. 36.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.