The text
(1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central heat pumps described in column 1 that are manufactured during the periods set out in column 4.
(1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central heat pumps described in column 1 that are manufactured during the periods set out in column 4.
(2) A split system central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central heat pump as defined in section 211.TABLE 1Column 1Column 2Column 3Column 4ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Split system central heat pumps, other than those that are small-duct and high-velocityCSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumptionSeasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.1Off mode power consumption ≤ 33 WOn or after December 31, 1998 and before January 1, 20232Split system central heat pumps that are small-duct and high-velocityCSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumptionSeasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.3Off mode power consumption ≤ 30 WOn or after December 31, 1998 and before January 1, 20233Split system central heat pumps, other than those that are small-duct and high-velocity or space-constrained10 C.F.R. Appendix M1Seasonal energy efficiency ratio 2 ≥ 14.3Heating seasonal performance factor 2 (Region V) ≥ 6.0Off mode power consumption ≤ 33 WOn or after January 1, 2023 and before January 1, 20254Split system central heat pumps that are small-duct and high-velocity10 C.F.R. Appendix M1Seasonal energy efficiency ratio 2 ≥ 12.0Heating seasonal performance factor 2 (Region V) ≥ 4.9Off mode power consumption ≤ 30 WOn or after January 1, 2023 and before January 1, 20255Split system central heat pumps that are space-constrained10 C.F.R. Appendix M1Seasonal energy efficiency ratio 2 ≥ 11.9Heating seasonal performance factor 2 (Region V) ≥ 5.0Off mode power consumption ≤ 33 WOn or after January 1, 2023 and before January 1, 20256Split system central heat pumps, other than those that are small-duct and high-velocity or space-constrained10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F)Seasonal energy efficiency ratio 2 ≥ 14.3Heating seasonal performance factor 2 (Region V) ≥ 6.0Off mode power consumption ≤ 33 WOn or after January 1, 20257Split system central heat pumps that are small-duct and high-velocity10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F)Seasonal energy efficiency ratio 2 ≥ 12.0Heating seasonal performance factor 2 (Region V) ≥ 4.9Off mode power consumption ≤ 30 WOn or after January 1, 20258Split system central heat pumps that are space-constrained10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F)Seasonal energy efficiency ratio 2 ≥ 11.9Heating seasonal performance factor 2 (Region V) ≥ 5.0Off mode power consumption ≤ 33 WOn or after January 1, 2025TABLE 2Column 1Column 2Column 3Column 4ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Split system central heat pumps, other than those that are small-duct and high-velocityCSA C656-14Seasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.1On or after December 31, 1998 and before January 1, 20262Split system central heat pumps that are small-duct and high-velocityCSA C656-14Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.3On or after December 31, 1998 and before January 1, 20263Split system central heat pumps, other than those that are space-constrained or small-duct and high-velocity10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted Seasonal energy efficiency ratio 2 ≥ 14.3Heating seasonal performance factor 2 (Region V) ≥ 6.0On or after January 1, 20264Split system central heat pumps that are space-constrained10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conductedSeasonal energy efficiency ratio 2 ≥ 13.9Heating seasonal performance factor 2 (Region V) ≥ 5.6On or after January 1, 20265Split system central heat pumps that are small-duct and high-velocity10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conductedSeasonal energy efficiency ratio 2 ≥ 14.0Heating seasonal performance factor 2 (Region V) ≥ 5.5On or after January 1, 2026
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗
Made under Energy Efficiency Act, S.C. 1992, c. 36.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.