Energy Efficiency Regulations, 2016, SOR/2016-311

Section 205

Energy efficiency standards — single-phase

Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 205 · current to April 28, 2026 · regulation last amended October 9, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4. (1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4. (2) A single package central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package central heat pump as defined in section 203.TABLE 1Column 1Column 2Column 3Column 4ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocityCSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumptionSeasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.0Off mode power consumption ≤ 33 WOn or after February 3, 1995 and before January 1, 20232Single package central heat pumps that are through-the-wallCSA C656-05 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumptionSeasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.4Off mode power consumption ≤ 33 WOn or after February 3, 1995 and before January 1, 20233Single package central heat pumps that are small-duct and high-velocityCSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumptionSeasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.3Off mode power consumption ≤ 30 WOn or after February 3, 1995 and before January 1, 20234Single package central heat pumps, other than those that are space-constrained10 C.F.R. Appendix M1Seasonal energy efficiency ratio 2 ≥ 13.4Heating seasonal performance factor 2 (Region V) ≥ 5.4Off mode power consumption ≤ 33 WOn or after January 1, 2023 and before January 1, 20255Single package central heat pumps that are space-constrained10 C.F.R. Appendix M1Seasonal energy efficiency ratio 2 ≥ 11.9Heating seasonal performance factor 2 (Region V) ≥ 5.0Off mode power consumption ≤ 33 WOn or after January 1, 2023 and before January 1, 20256Single package central heat pumps, other than those that are space-constrained10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conductedSeasonal energy efficiency ratio 2 ≥ 13.4Heating seasonal performance factor 2 (Region V) ≥ 5.4Off mode power consumption ≤ 33 WOn or after January 1, 20257Single package central heat pumps that are space-constrained10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conductedSeasonal energy efficiency ratio 2 ≥ 11.9Heating seasonal performance factor 2 (Region V) ≥ 5.0Off mode power consumption ≤ 33 WOn or after January 1, 2025TABLE 2Column 1Column 2Column 3Column 4ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocityCSA C656-14Seasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.0On or after February 3, 1995 and before January 1, 20232Single package central heat pumps that are through-the-wallCSA C656-05Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.4On or after February 3, 1995 and before January 1, 20233Single package central heat pumps that are small-duct and high-velocityCSA C656-14Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.3On or after February 3, 1995 and before January 1, 20234Single package central heat pumps, other than those that are space-constrainedCSA C656-14Seasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.0On or after January 1, 2023 and before January 1, 20265Single package central heat pumps that are space-constrainedCSA C656-14Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.4On or after January 1, 2023 and before January 1, 20266Single package central heat pumps, other than those that are space-constrained10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conductedSeasonal energy efficiency ratio 2 ≥ 13.4Heating seasonal performance factor 2 (Region V) ≥ 5.3On or after January 1, 20267Single package central heat pumps that are space-constrained10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conductedSeasonal energy efficiency ratio 2 ≥ 13.9Heating seasonal performance factor 2 (Region V) ≥ 5.3On or after January 1, 2026
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗

Made under Energy Efficiency Act, S.C. 1992, c. 36.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.