Energy Efficiency Regulations, 2016, SOR/2016-311

Section 197

Energy efficiency standards

Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 197 · current to April 28, 2026 · regulation last amended October 9, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have no heating section or have an electric heating section. (2) The energy efficiency standards set out in column 3 of Table 2 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have a heating section other than an electric heating section. (3) A large heat pump complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large heat pump as defined in section 195.TABLE 1Column 1Column 2Column 3Column 4ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-98Energy efficiency ratio ≥ 10.1Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet airOn or after December 31, 1998 and before January 1, 20102Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEEREnergy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 11.2On or after January 1, 2010 and before January 1, 20183Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-17Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 12.2On or after January 1, 2018 and before January 1, 20264Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-17 or 10 C.F.R. Appendix AEnergy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.4 with 8.3°C inlet air and ≥ 2.25 with −8.3°C inlet airIEER ≥ 14.1On or after January 1, 20265Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-98Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with −8.3°C inlet airOn or after December 31, 1998 and before January 1, 20106Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEEREnergy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.7On or after January 1, 2010 and before January 1, 20187Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-17Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 11.6On or after January 1, 2018 and before January 1, 20268Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-17 or 10 C.F.R. Appendix AEnergy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 13.5On or after January 1, 20269Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kWCSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEEREnergy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 9.6On or after January 1, 2010 and before January 1, 201810Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kWCSA C746-17Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.6On or after January 1, 2018 and before January 1, 202611Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kWCSA C746-17 or 10 C.F.R. Appendix AEnergy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 12.5On or after January 1, 2026TABLE 2Column 1Column 2Column 3Column 4ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-98Energy efficiency ratio ≥ 9.9Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet airOn or after December 31, 1998 and before January 1, 20102Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEEREnergy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 11.0On or after January 1, 2010 and before January 1, 20183Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-17Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 12.0On or after January 1, 2018 and before January 1, 20264Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-17 or 10 C.F.R. Appendix AEnergy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.4 with 8.3°C inlet air and ≥ 2.25 with −8.3°C inlet airIEER ≥ 13.9On or after January 1, 20265Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-98Energy efficiency ratio ≥ 9.1Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with −8.3°C inlet airOn or after December 31, 1998 and before January 1, 20106Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEEREnergy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.5On or after January 1, 2010 and before January 1, 20187Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-17Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 11.4On or after January 1, 2018 and before January 1, 20268Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-17 or 10 C.F.R. Appendix AEnergy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 13.3On or after January 1, 20269Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kWCSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEEREnergy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 9.4On or after January 1, 2010 and before January 1, 201810Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kWCSA C746-17Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.4On or after January 1, 2018 and before January 1, 202611Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kWCSA C746-17 or 10 C.F.R. Appendix AEnergy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 12.3On or after January 1, 2026
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗

Made under Energy Efficiency Act, S.C. 1992, c. 36.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.