Reduction of Carbon Dioxide Emissions from Coal-fired Generation of Electricity Regulations, SOR/2012-167

Section 21

Quantification

Cite as Reduction of Carbon Dioxide Emissions from Coal-fired Generation of Electricity Regulations, SOR/2012-167, s. 21 · current to July 24, 2025 · regulation last amended November 30, 2018

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) If paragraph 20(1)(a) applies, the quantity of CO2 emissions referred to in subsection 20(1) is to be determined in accordance with the following formula:Eu – Ebio + Enon-ccswhereEuis the quantity of CO2 emissions, expressed in tonnes, from the unit, “u”, during the calendar year from the combustion of fuel, as measured by the CEMS in accordance with sections 7.1 to 7.7 of the Reference Method;Ebiois the quantity of CO2 emissions, expressed in tonnes, from the combustion of biomass in the unit during the calendar year, determined(a) by using a fuel-based method(i) in accordance with paragraph 24(1)(a) or (b), if the unit combusts solid biomass at an average daily rate of less than 3t/day during the given calendar year, and(ii) in accordance with the applicable formula set out in one of paragraphs 23(1)(a) to (c) for the type of biomass combusted, in any other case, or(b) by using the method, based on data from the CEMS, described in subsection (2); andEnon-ccsis the quantity of CO2 emissions, expressed in tonnes, from the combustion of fuel in the unit, including those emissions referred to in subsection 3(4), during the calendar year — other than the quantity of those emissions as measured by the CEMS and set out in the description of Eu — that is determined using a direct measure of the flow of, and the concentration of CO2 in, the emissions from that combustion of fuel but that is not ultimately captured, transported and stored as described in subsection 3(5). (2) For the purpose of determining the value of Ebio, the method, based on data from the CEMS, consists of making the following sequence of determinations: (a) the volume of CO2 emitted from combustion of fuel in the unit for each hour of production of electricity during the calendar year determined in accordance with the following formula:0.01 × %CO2w,h × Qw,h × thwhere%CO2w,his the average concentration of CO2 in relation to all gases in the stack emitted from the combustion of fuel in the unit during a given hour, “h”, during which the unit produced electricity in the calendar year — or, if applicable, a calculation made in accordance with section 7.4 of the Reference Method of that average concentration of CO2 based on a measurement of the concentration of oxygen (O2) in those gases in the stack — expressed as a percentage on a wet basis,Qw,his the average volumetric flow during that hour, measured on a wet basis by the stack gas volumetric flow monitor, expressed in standard m3, andthis the period during which the unit produced electricity, expressed in hours; (b) the volume of CO2 emitted from combustion of fossil fuel in the unit during the calendar year, expressed in standard m3 and referred to in this subsection as Vff, determined in accordance with the following formula:The formula for determining the volume of CO2 emissions emitted from the combustion of fossil fuel in the unit during the calendar year is the sum of the products resulting from the multiplication of Qi, Fc,i and HHVd,i for each fossil fuel type “i” combusted in the unit during the calendar year.whereQiis the quantity of fossil fuel type “i” combusted in the unit during the calendar year, determined(a) for a solid fuel, in the same manner as the one used in the determination of Mf in the formula set out in paragraph 23(1)(a) and expressed in tonnes,(b) for a liquid fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(b) and expressed in kL, and(c) for a gaseous fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(c) and expressed in standard m3,iis the ith fossil fuel type combusted in the unit during the calendar year, with “i” going from the number 1 to n, where n is the number of fossil fuels so combusted,Fc,iis the fuel-specific carbon-based F-factor for each fossil fuel type “i” — being, as the case may be, the default value as set out in column 3 of the table to subsection (3) for that fuel type set out in column 2 or determined for that fuel type in accordance with Appendix A of the Reference Method — expressed in standard m3 of CO2/GJ,HHVd,i— expressed in GJ/tonne, for a solid fuel, in GJ/kL, for a liquid fuel, and in GJ/standard m3, for a gaseous fuel — is, for each fossil fuel type “i”,(a) the default higher heating value set out in column 2 of Schedule 5 for that fuel type set out in column 1, and(b) in the absence of a default higher heating value for that fuel type referred to in paragraph (a), a default higher heating value for that fuel type established by a body that is internationally recognized as being competent to establish default higher heating values for fuels; (c) the volume of CO2 emitted from the combustion of biomass in the unit during the calendar year, expressed in standard m3 and referred to in this subsection as Vbio, determined in accordance with the following formula:VT – VffwhereVTis the sum of the volumes of CO2 emitted from combustion of fuel in the unit during each hour of production of electricity during the calendar year, as determined under paragraph (a), andVffis Vff determined in accordance with the formula set out in paragraph (b); and (d) the quantity of the CO2 emissions from the combustion of biomass in the unit during the calendar year, namely Ebio determined in accordance with the formula set out in subsection (1), based on the following two determinations: (i) the fraction of the volume of CO2 emissions from all fuel combusted in the unit attributable to the combustion of biomass in the unit during the calendar year, referred to in this section as Biofr, determined in accordance with the following formula:The formula for determining the fraction of the volume of CO2 emissions from all fuel combusted in the unit during the calendar year attributable to the combustion of biomass is the quotient of Vbio over VT.whereVbiois the volume of CO2 emitted from the combustion of biomass in the unit during the calendar year determined in accordance with the formula set out in paragraph (c),VTis the value of VT determined in accordance with the formula set out in paragraph (c), and (ii) the quantity of CO2 emissions described by Ebio determined in accordance with the following formula:(Biofr× Eu) – EswhereBiofris the fraction of the volume of CO2 emissions from all fuel combusted in the unit attributable to the combustion of biomass in the unit during the calendar year determined in accordance with the formula set out in subparagraph (i),Euis the value of Eu determined in the formula set out in subsection (1), andEsis the quantity of CO2 emissions, expressed in tonnes, that is released from the use of sorbent to control the emission of sulphur dioxide from the unit during the calendar year, determined in accordance with the following formula:The formula for determining the value of CO2 emissions released from the use of sorbent during a calendar year is the product resulting from the multiplication of S, R and the quotient of the constant 44 over MMs.whereSis the quantity of calcium carbonate (CaCO3) or other sorbent material so used, expressed in tonnes,Ris the stoichiometric ratio, on a mole fraction basis, of CO2 released on usage of one mole of sorbent material, where R=1 if the sorbent material is CaCO3, andMMsis the molecular mass of the sorbent material, where MMs = 100 if the sorbent material is CaCO3. (3) The default value for the fuel-specific carbon-based F-factor for certain types of fossil fuel is set out in column 3 of the following table:TABLEColumn 1Column 2Column 3ItemFossil fuelTypeF-factor (standard m3/GJ)1CoalAnthracite54.2Bituminous49.2Sub-bituminous49.2Lignite53.02OilCrude, residual or distillate39.33GasNatural28.4Propane32.5 (4) Despite subsection (1), if there is one or more other units at a power plant where a unit is located and a CEMS measures emissions from that unit and from one or more of those other units at a common stack rather than at the exhaust duct of that unit and of each of those other units that brings those emissions to the common stack, then the quantity of emissions attributable to that unit for the purpose of subsection (1) is determined based on the ratio of the heat input of that unit to the total of the heat input of that unit and of all of those other units sharing the common stack in accordance with the following formula:The formula for determining the quantity of emissions attributable to a unit that shares a common emissions stack is the product of the multiplication of E and the quotient of the following two sums: the sum of the product resulting from the multiplication of Quj and HHVuj for each fuel type “j” combusted in that unit “u” during the calendar year and the sum, for each unit “i” that shares a common stack, of the sum of the product resulting from the multiplication of Qij and HHVij for each fuel type “j” combusted during the calendar year.whereQujis the quantity of fuel type “j” combusted in that unit “u” during the calendar year, determined(a) for a solid fuel, in the same manner as the one used in the determination of Mf in the formula set out in paragraph 23(1)(a) and expressed in tonnes,(b) for a liquid fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(b) and expressed in kL, and(c) for a gaseous fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(c) and expressed in standard m3;HHVujis the higher heating value, determined in accordance with section 24 and expressed in the applicable unit of measure referred to in that section of fuel type “j” combusted during the calendar year in that unit “u”;iis the ith unit located at the power plant with “i” going from the number 1 to n, where n is the number of units that share a common stack;jis the jth fuel type, including types of biomass, combusted during the calendar year in a unit located at the power plant with “j” going from the number 1 to m, where m is the number of those fuel types;Qijis the quantity of fuel type “j” combusted in each unit “i” during the calendar year, determined for a solid fuel, a liquid fuel and a gaseous fuel, respectively, in the manner set out in the description of Quj;HHVijis the higher heating value, determined in accordance with section 24 and expressed in the applicable unit of measure referred to in that section, of fuel type “j” combusted during the calendar year in unit “i”; andEis the quantity of CO2 emissions, expressed in tonnes, from the combustion of fuels in all the units during the calendar year, measured by a CEMS at the common stack in accordance with subsection 21(1).
Read the Reduction of Carbon Dioxide Emissions from Coal-fired Generation of Electricity Regulations on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.