(1) A watertight compartment on a vessel shall be provided with a means of pumping or with access for bailing when the vessel is in any operating condition, unless the vessel cannot retain a sufficient quantity of water to make it capsize or the compartment is sealed and is not readily accessible. (2) If the bilge space on a vessel is not easily visible from the operating position, the space shall, in accordance with the construction standards, be fitted with (a) an automatic high bilge-water alarm; and (b) a bilge pumping system or, in the case of a vessel that is not more than 12 m in length, a permanently installed automatic bilge pump that is connected to an indicator showing when the pump is running and to an overriding manual switch, both of which are to be located at the operating position. (3) An automatic bilge pump or a bilge pumping system shall have a minimum capacity of 0.91 L/s.
Read the Small Vessel Regulations on the Justice Laws Website ↗

Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.