Small Vessel Regulations, SOR/2010-91
Section 731
Cite as Small Vessel Regulations, SOR/2010-91, s. 731 · current to January 19, 2026 · regulation last amended December 31, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) An electrical component shall be certified by a product certification body or a testing laboratory as being ignition-protected in accordance with
(a) Society of Automotive Engineers Recommended Practice SAE J1171, External Ignition Protection of Marine Electrical Devices; or
(b) Underwriters Laboratories, Inc. Standard UL 1500, Ignition-Protection Test for Marine Products.
(2) Subsection (1) does not apply if
(a) the vessel uses diesel as its only fuel source;
(b) the electrical component is isolated, in accordance with the specifications set out in the construction standards, from fuel sources such as
(i) engines and cooking appliances,
(ii) valves, connections or other fittings on vent lines, fill lines or distribution lines, and
(iii) fuel tanks; or
(c) the electrical component is located in a compartment where the only source of flammable vapour is from liquified-petroleum-gas or compressed-natural-gas appliances, cylinders, fittings, valves or regulators, and the compartment
(i) has, for every cubic metre of net internal volume, at least 0.34 m2 of open area exposed to the atmosphere outside the vessel, or
(ii) is an accommodation space.
Read the Small Vessel Regulations on the Justice Laws Website ↗
Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.