Small Vessel Regulations, SOR/2010-91
Section 512
Cite as Small Vessel Regulations, SOR/2010-91, s. 512 · current to January 19, 2026 · regulation last amended December 31, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) A workboat of a length set out in column 1 of the table to this subsection shall carry on board the firefighting equipment set out in column 2 as indicated in that column.tableColumn 1Column 2ItemLengthFirefighting Equipment1not more than 6 m(a) a 1A:5B:C portable fire extinguisher; and(b) a 1A:5B:C portable fire extinguisher, if the vessel is equipped with a fuel-burning cooking, heating or refrigerating appliance2more than 6 m but not more than 9 m(a) a 2A:10B:C portable fire extinguisher;(b) a 2A:10B:C portable fire extinguisher, if the vessel is equipped with a fuel-burning cooking, heating or refrigerating appliance; and(c) a 10B:C portable fire extinguisher at the entrance to the engine space3more than 9 m but not more than 12 m(a) a 2A:10B:C portable fire extinguisher;(b) a 2A:10B:C portable fire extinguisher at each access to a space fitted with a fuel-burning cooking, heating or refrigerating appliance;(c) a 10B:C portable fire extinguisher at the entrance to the engine space;(d) a fire axe; and(e) a fire bucket4more than 12 m(a) a 2A:20B:C portable fire extinguisher;(b) a 2A:20B:C portable fire extinguisher at the following locations:(i) at each access to a space fitted with a fuel-burning cooking, heating or refrigerating appliance, and(ii) at the entrance to each accommodation space;(c) a 20B:C portable fire extinguisher at the entrance to the engine space;(d) a manual or power-driven fire pump, located outside the engine space, that conforms to the construction standards;(e) a fire hose and nozzle from which a jet of water can be directed into any part of the vessel;(f) a fire axe; and(g) two fire buckets
(2) A workboat that is not power-driven and is not equipped with an electrical system is not required to carry on board the portable fire extinguisher set out in paragraph (a) of items 1 to 4 of the table to subsection (1).
(3) The portable fire extinguishers set out in the table to subsection (1) shall be mounted with a clamp or bracket that provides a quick and positive release.
(4) A portable fire extinguisher intended for use in an accommodation space, or stored in an accommodation space, shall not contain a gas extinguishing agent.
Read the Small Vessel Regulations on the Justice Laws Website ↗
Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.