Canada Oil and Gas Drilling and Production Regulations, SOR/2009-315

Section 62

Cite as Canada Oil and Gas Drilling and Production Regulations, SOR/2009-315, s. 62 · current to January 19, 2026 · regulation last amended December 31, 2009

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

The operator shall ensure (a) that meters and associated equipment are calibrated and maintained to ensure their continued accuracy; (b) that equipment used to calibrate the flow system is calibrated in accordance with good measurement practices; (c) that any component of the flow system that may have an impact on the accuracy or integrity of the flow system and that is not functioning in accordance with the manufacturer’s specifications is repaired or replaced without delay, or, if it is not possible to do so without delay, corrective measures are taken to minimize the impact on the accuracy and integrity of the flow system while the repair or replacement is proceeding; and (d) that a conservation officer is notified, as soon as the circumstances permit, of any malfunction or failure of any flow system component that may have an impact on the accuracy of the flow system and of the corrective measures taken.
Read the Canada Oil and Gas Drilling and Production Regulations on the Justice Laws Website ↗

Made under Canada Oil and Gas Operations Act, R.S.C. 1985, c. O-7.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.